Pelco C2429M Manual Do Utilizador

Página de 16
10
Pelco Installation Manual C2429M (3/01)
APPENDIX
Table A.  Video Coaxial Cable Wiring Distances
Cable Type*
Maximum Distance
RG59/U
750 ft (229 m)
RG6/U
1,000 ft (305 m)
RG11/U
1,500 ft (457 m)
* Minimum cable requirements:
75 ohms impedance. All-copper center conductor.
95% braided copper shield.
Table B.  24 VAC Wiring Distances
The following are the recommended maximum distances for 24 VAC with a
10-percent voltage drop. (Ten percent is generally the maximum allowable
voltage drop for AC-powered devices.)
Wire Gauge
20
18
16
14
12
10
30 vA
94 ft
150 ft
238 ft
380 ft
603 ft
960 ft
(28 m)
(45 m
(115 m)
 (72 m)
(183 m)
 (292 m)
75 vA
37 ft
60 ft
95 ft
152 ft
241 ft
384 ft
(11 m)
(18 m)
(29 m)
(46 m)
(73 m)
(117 m)
NOTE: Input power for the dome is 24 VAC only. Power consumption is 30 vA
per dome for indoor models and 75 vA for outdoor models.
Use a 24 VAC transformer with the following minimum vA:
40 vA per dome
For indoor models (without heater)
100 vA per dome
For outdoor models (with heater)
Table C.  Switch Settings for SW1
Control Type
Switch Setting
SW1-1
SW1-2
SW1-3
SW1-4
SW1-5
SW1-6
SW1-7
SW1-8
Coaxitron
®
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF**
P-Type Control
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF**
D-Type Control
OFF
ON
OFF
OFF
OFF
OFF
OFF*
OFF**
NOTES: Switches SW 1-3 through SW 1-6 MUST be OFF.
D-type control is RS-422 that is compatible with Pelco’s CM6700, MPT9500, CM8500, and Genex
®
 controllers or with
American Dynamics control systems using the AD2083 Translator.
P-type control is RS-422 that is compatible with Pelco’s CM6700/CM9750/CM9760 and Genex
 
control systems.
* OFF- Use with controllers that have more than 32 presets.
ON- Use with American Dynamics controllers (32 presets).
** OFF - Use with all control systems except CM9502 with variable speed keyboards.
For CM9502 with fixed speed keyboards, set switch OFF.