Toshiba EM1-31071 Manual Do Utilizador
11-23
11. PROGRAMMING PROCEDURES
11.14 LON SYSTEM
Data Transmission
The following data are down-line-loaded.
Page 1: (0). All (PLU+ING+NUTRI)
Page 2: (0). SPEED KEY
(1). PLU
(1). LOGO
(2). ING.
(2). VENDOR
(3). NUTRITION
(3). FREE FORMAT
(4). U. PRICE
(9). CHANGE PAGE
(5). DATE/TIME
(7). LOCK SCALE (Check the LON cable)
(8). OPEN SCALE (Release the lock after checking the LON cable.)
(9). CHANGE PAGE
(7). LOCK SCALE (Check the LON cable)
(8). OPEN SCALE (Release the lock after checking the LON cable.)
(9). CHANGE PAGE
The error terminal
ID# is displayed. Use
the and
keys.
ID# is displayed. Use
the and
keys.
Select one of the above using the
and keys.
and keys.
Release the scale from the error.
0: CANCEL
1: RETRY
2: CONTINUE
1: RETRY
2: CONTINUE
Select a DLL data
using the
and keys.
using the
and keys.
Release the scale
from the error.
from the error.
LOCK SCALE method
NEXT PLU
NEXT PLU
NEXT PLU
–
–
–
ENTER
CLEAR
p
n
Errorous terminal
# is displayed.
# is displayed.
NOTE:
DLL is performed automatically in the following two ways. It is selectable by the Initial
Settings #0-6 and #0-7.
(1) LOCK SCALE method
Settings #0-6 and #0-7.
(1) LOCK SCALE method
Step 1:
“LOCK SCALE” is sent. (*1)
Step 2:
Selected data is sent. (*2)
Step 3:
“OPEN SCALE” is sent.
*1: If an error occurs during step 1, the error terminal ID# is indicated. Select
“cancel”, “retry” or “continue” to release the terminal from an error.
cancel:
Quits the operation after sending “OPEN SCALE”
retry:
Tries to send “LOCK SCALE” again.
continue:
Ignores the error terminal and starts DLL.
*2 If an error occurs during step 2, the error terminal ID# is indicated. Press the
CLEAR key to return to the DLL data selection menu.
(2) Background DLL
Step 1:
Selected data is sent. (*3)
*3 If an error occurs, the error terminal ID# is indicated. Press the CLEAR key to
return to the DLL data selection menu.