A.0500.551 – IM-TGMAG/02.00 EN (02/2008)
3.18.5.4  Strainer
Foreign particles can seriously damage the pump. Avoid the entry of these particles by installing a 
strainer.
•  When selecting the strainer attention should be given to the size of the openings so that pres-
sure losses are minimised. The cross-sectional area of the strainer must be three times that of 
the suction pipe.
•  Install the strainer in such a way that maintenance and cleaning are possible.
•  Make sure that the pressure drop in the strainer is calculated with the right viscosity. Heat the
strainer if necessary to reduce viscosity and pressure drop.
For the maximum allowable particle size see section 3.15.
3.18.6  Secondary piping
For dimensions of connections and plugs see chapter 6.0.
3.18.6.1  Drain lines
The pump is provided with a drain plug.
3.18.6.2  Heating  jackets
1.  S-type jackets
The S-jackets are designed for use with saturated steam (max 10 bar, 180°C) or with non-dangerous 
media. They are provided with threaded connections Bl (see chapter 6.0 for the dimensions). 
The connection can be done by threaded pipes or pipe connections with sealing in the thread  
(conical thread applying ISO 7/1) or sealed outside the thread by means of flat gaskets (cylindrical 
thread applying ISO 228/1). Thread type see section 3.21.7.
S-jacket on the pump cover
2. T-type jackets
The T-jackets are provided with special steel flanges (delivered with the pump) on which the pipes 
should be welded properly by qualified personnel. The jackets are made of nodular iron or other 
ductile material. For pipe dimensions of Cf see chapter 6.0.