Star Trac 7600 Manual Do Utilizador
Service Manual: E-TR and E-TRi
26
DISPLAY PARAMETERS
Parameter Defaults
The following parameters can be accessed by entering the Maintenance Mode. When installing a
new display electronic board, it will come with factory default settings. Depending on the model and
voltage of unit you are installing the board into, you may need to adjust your settings by referencing
the following chart.
new display electronic board, it will come with factory default settings. Depending on the model and
voltage of unit you are installing the board into, you may need to adjust your settings by referencing
the following chart.
Parameter
110V Setting
220V Setting
Default
Parameter Ranges
UNITS
ENGLISH
ENGLISH,
METRIC
MINIMUM SPEED
0.5
(0.8kph)
0.5
(0.8kph)
0.5
(0.8kph)
0.5 – 5.0
(0.8 – 8.0kph)
MAXIMUM SPEED
10.0
(16.0kph)
12.0
(20.0kph)
12.5
(kph)
5.0 – 12.5
(8.0 – 20.0kph)
ELEVATION
ON
OFF,
ON
TIME
99
20 - 99
OPER HOURS
0
0 – 65535
DISTANCE
0
0 – 65535
WEIGHT
155
0 – 350
SERIAL NO
0
0 – 65535
LANGUAGE
ENGLISH ENGLISH, DUTCH, FRENCH,
GERMAN, PORTUGUESE,
SPANISH, SWEDISH, ITALIAN,
KATAKANA
ENTRY
UNITS
UNITS,
TENTHS
HEART RATE
BOTH
CONTACT, POLAR, BOTH
METS
OFF
OFF,
ON
WATTS
OFF
OFF,
ON
PAUSE
45
20 – 120
SCALE
ON
OFF,
ON
INFRARED COM
ON
OFF,
ON
CSAFE
ON
OFF,
ON
FAN
ON
OFF,
ON
AUTO STOP
OFF
OFF,
ON
ENTERTAINMENT
OFF
OFF,
ON
ACCELERATION TIME
35
25 – 60
DECELERATION TIME
30
20 - 60
LOCK OUT
OFF
OFF,
ON
LOCK OUT ID
12345
0 - 65535
RAIL STOP
ON
OFF,
ON
STOP SWITCH
E-STOP
E-STOP,
LANYARD
10_REV
376
376
376
0 – 740
CNT/REV
31
31
31
0 – 125
MINUMUM PWM
(VARIES)
(VARIES)
34
0 – 110
1/2 MAXIMUM
(VARIES)
(VARIES)
200
0 – 340
MAXIMUM PWM
(VARIES)
(VARIES)
400
0 – 495
PERSON DETECT 1
17
17
17
0 – 150
PERSON DETECT 2
30
30
30
0 – 150
PERSON DETECT 3
40
40
40
0 – 150
DATE
1.98
0.00 – 9.99