Star Trac 7600 Manual Do Utilizador

Página de 68
 
 
 
Service Manual: E-TR and E-TRi 
 
33
CSAFE TEST 
This parameter is used by Star Trac at the factory. 
 
HEART RATE TEST 
The Heart Rate Test mode can be used to simultaneously test the function and response for 
both the contact and Polar heart rate systems. 
 
 
 
Ÿ Press ‘Start’ key 
Display will read  POLAR   0 CONTACT  0 
 
, , Grab the HR grips 
CONTACT  X  should detect your heart rate then display the reading 
 
(If applicable) Polar strap 
*If you have a Polar transmitter or a polar signal simulator then signal will be detected 
and processed by the Polar system and display the value as  POLAR   X 
 
Ÿ Press ‘Stop’ key twice to return to the MAINTENANCE MODE 
 
 
 
INFRARED TEST 
This parameter is used by Star Trac at the factory. 
 
LAST ERROR LIST 
The Last Error List is a list bank of the last five issues the unit has captured into its memory for 
diagnosis of an issue.  To access the Last Error list banks, follow the procedure below.  For 
more information including DFR, see the DFR section in this manual. 
 
 
 
Ÿ Press ‘Start’ key 
Display will enter DISPLAY TEST and await your next command 
 
Ÿ Press ‘Start’ key 
Display will cycle thru a self test and display all led’s in a sequenced pattern 
 
Ÿ Press ‘Stop’ key twice to return to the MAINTENANCE MODE 
 
 
 
Ÿ Press ‘Start’ key 
Display will enter DISPLAY TEST and await your next command 
 
Ÿ Press ‘1’ key 
MC1 Vx.x CKSM xxxx will display 
 
 
Ÿ Press ‘Speed Plus’ key 
MC2 Vx.x CKSM xxxx will display   
 
º 
 
Ÿ Press ‘Speed Minus’ key 
MC1 Vx.x CKSM xxxx will display    
¼  
  Loop 
 
Ÿ Press ‘Stop’ key twice to return to the MAINTENANCE MODE 
 
 
 
Ÿ Press ‘Start’ key 
Display will enter DISPLAY TEST and await your next command 
 
Ÿ Press ‘2’ key 
Display will read KEYBOARD TEST 
 
Ÿ Press any key except ‘Stop’ to verify function. 
 
Ÿ Press ‘Stop’ key to verify function then press again to return to the MAINTENANCE MODE 
 
 
 
When opening the banks, #1 is the first code that was captured, #2 the second, #3 the third 
and so on.  If more than 5 codes have been captured, bank #5 will always be the latest code 
captured and the previous number will be replaced accordingly. 
 
For a list of definitions for the Last Error List, see the LAST ERROR LIST DEFINITIONS 