Belden DataTwist Cat3 2PR 24AWG cable, 305m 1227A1 Manual Do Utilizador
Códigos do produto
1227A1
1227A1 Paired - DataTwist® 3 UTP Cable
Min. Bend Radius (Install)
0.8 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification
CMR, UL444
IEEE Specification
802.3 10BaseT, 100BaseT4
TIA/EIA Specification
568-B.2 Category 3
Other Specification
NEMA WC-63 Category 3, UL verified to TIA/EIA-568-B.2, Category 3
FLAME TEST:
UL Flame Test
UL1666 Riser
CSA Flame Test
FT4
PLENUM/NON-PLENUM:
Plenum (Y/N)
N
Plenum Number
1243A2
ELECTRICAL CHARACTERISTICS:
Nom. Mutual Capacitance @ 1 KHz
15 pF/ft
Nom. Mutual Capacitance @ 1 KHz
15 pF/ft
Maximum Capacitance Unbalance (pF/100 m)
330 pF/100 m
Nominal Velocity of Propagation
70 %
Nominal Delay
1.5 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C
28.0 Ohms/1000 ft
Maximum Conductor DC Resistance @ 20 Deg. C
9.38 Ohms/100 m
Maximum DCR Unbalance @ 20 Deg. C
5 %
Max. Operating Voltage - UL
300 V RMS
ELECTRICAL CHARACTERISTICS - PREMISE:
Premise Cable Electricals :
Frequency (MHz)
Max. Attenuation
(dB/100 m)
(dB/100 m)
Min. NEXT (dB)
Min. PSNEXT (dB)
Min. Structural
Return Loss (dB)
Return Loss (dB)
Fitted Impedance
(Ohms)
(Ohms)
1
2.56
41.0
No Spec
12.0
100 ± 15%
4
5.58
32.0
No Spec
12.0
100 ± 15%
8
8.50
27.0
No Spec
12.0
100 ± 15%
10
9.71
26.0
No Spec
12.0
100 ± 15%
16
13.10
23.0
No Spec
9.96
100 ± 15%
PUT-UPS AND COLORS:
Item
Description
Put-Up (ft.)
Ship Weight (lbs.)
Jacket Color
Notes
1227A1 008U1000
2 PR #24 PP PVC
U1000
13
GRAY
Revision Number: 2 Revision Date: 05-26-2004
Page 2 of 3