IBM 760C/CD (9546) Manual Do Utilizador
Note: If the replaced parts did not resolve the
problem, put the original parts back in the IBM
ThinkPad Dock I. Do not replace
non-defective parts.
ThinkPad Dock I. Do not replace
non-defective parts.
a. Keyboard cable
b. Main card of IBM ThinkPad Dock I
How to Run the Diagnostics
Use either the TrackPoint III or the cursor move keys to
interact with the tests. The Enter key works the same as
selecting the OK icon to reply OK.
interact with the tests. The Enter key works the same as
selecting the OK icon to reply OK.
1. Press and hold the F1 key; then power-on the
computer. Hold the F1 key down until the
Easy-Setup screen appears.
Easy-Setup screen appears.
2. Select Test and press Enter.
3. Select a device and press Enter to run the test.
4. The test progress screen appears.
5. OK appears when the test ends without any errors.
6. Start the Advanced Diagnostic test by pressing
3. Select a device and press Enter to run the test.
4. The test progress screen appears.
5. OK appears when the test ends without any errors.
6. Start the Advanced Diagnostic test by pressing
Ctrl
+
A on the basic diagnostic menu screen.
7. Select Tool to install the tools.
8. Select a device, press the Spacebar and install the
8. Select a device, press the Spacebar and install the
tool. Multiple devices can be selected by repeating
this step.
this step.
A
√
mark appears beside the selected devices.
9. Select OK and press Enter if the selection is OK.
10. Select a device and press Enter to start the tests.
11. Select Test All to test all devices.
12. Select Loop Test to run the tests in a repeated loop.
11. Select Test All to test all devices.
12. Select Loop Test to run the tests in a repeated loop.
A loop option menu appears in which a device loop or
all-device loop can be selected. Select a device and
press the Spacebar to select a device. Repeat this
step to select multiple devices. Press Enter to start
the diagnostic loop. If no device is selected, all
device tests are looped.
all-device loop can be selected. Select a device and
press the Spacebar to select a device. Repeat this
step to select multiple devices. Press Enter to start
the diagnostic loop. If no device is selected, all
device tests are looped.
13. To exit the loop, keep pressing Ctrl
+
Pause until the
test exits. A beep sounds to notify that the exit
interrupt is sensed by the test program.
interrupt is sensed by the test program.
Error Log:
Diagnostic errors are printed on the printer
that is attached to parallel port when the error is detected.
The error is also logged in the system memory.
The error is also logged in the system memory.
Use the following procedure to display the errors.
1. End the test, if it is running.
2. Press Ctrl
2. Press Ctrl
+
A to select the advanced diagnostic mode.
3. Press Ctrl
+
E.
4. The error log appears.
5. To exit the screen, select the cancel icon or press
5. To exit the screen, select the cancel icon or press
Esc.
The error log is not saved when system power is turned
off.
off.
ThinkPad SelectaDock Docking System
557