NorthStar Navigation D210 Manual Do Utilizador

Página de 12
Northstar Explorer D210 Installation and Operation Manual
5
Keel/Surface Offset
An offset may be automatically added to 
or subtracted from the depth reading to 
compensate for the location of the transducer. 
This allows the instrument to indicate the water 
depth relative to the bottom of the keel or the 
surface of the water.
To set the keel/surface offset:
1.  Apply power while holding down 
.
Hold down during power up
2.  When the unit is on, release 
. The display 
will indicate if the current offset is keel offset 
or waterline offset:
Hull Offset (Depth below the keel)
Surface Offset (Depth below the surface)
3.  After 5 seconds the display will indicate the 
current offset.
2 Instrument Setup
Note: A negative offset is used to display depth 
below the keel and a positive offset is used to display 
depth below the surface.
4. Use   and 
 to change the value. If either 
key is held depressed for more than one 
second the reading will increase or decrease 
rapidly.
5.  The offset can be programmed in 0.1 unit 
steps from -9.9 to 9.9 feet (or equivalent). 
When programmed for a negative offset, ‘-’ 
will be indicated on the left hand side of the 
display.
6.  To display depth below the keel enter the 
vertical distance between the bottom of the 
keel and the depth transducer as a negative 
value.
7.  To display depth below surface enter the 
vertical distance from the waterline to the 
depth transducer as a positive number (no 
negative sign).
8.  To exit this mode, press and hold both 
 and 
 simultaneously. Alternatively, if no keys 
are pressed for a period of 5 seconds normal 
depth display will resume.
  
Press simultaneously
The display will now indicate the current water 
depth.
3. Use   and 
 to change the value. If either 
key is held depressed for more than one 
second the reading will increase or decrease 
rapidly.
4.  When the alarm is set, exit by pressing both 
 and 
 simultaneously. Alternatively, if no 
keys are pressed for a period of 5 seconds the 
normal depth display will resume.  
Press simultaneously to exit
Note: If the reading is increased one step above 600 
feet (or equivalent) the display will show OFF and 
the alarm will be disabled. The alarm can also be 
disabled by pressing both 
 and 
 for 5 seconds. 
The word OFF will be displayed but the alarm depth 
will be retained for future use.
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF