Model
TK-2140
TK-3140
GENERAL
Frequency Range
Type 1
136 ~ 174 MHz
450 ~ 490 MHz
Type 2
470 ~ 512 MHz
Type 3
400 ~ 430 MHz
Systems (Trunked mode)
Max. 32
Group (Trunked mode)
Max. 250
Channels
Trunked/Conventional format
Max. 600/Max. 250
Channel Spacing
Wide/Narrow
25, 30 kHz/12.5, 15 kHz 
25 kHz/12.5 kHz 
Channel Step
2.5, 5, 6.25, 7.5 kHz
5, 6.25 kHz
Operating Voltage
7.5 V DC ± 20 %
Battery Life (5-5-90 duty cycle, during hi-power, battery saver off)
with KNB-25A (1200mAh)
Approx. 8 hours
with KNB-26N (2000mAh)
Approx. 12 hours
with KNB-35L (1950mAh)
Approx. 11 hours
Operating Temperature Range*
-22° F ~ +140° F (-30° C ~ +60° C)
Frequency Stability 
±0.00025% (-22° F ~ +140° F)
Antenna Impedance
50 
Ω
Channel Frequency Spread
Type 1
38 MHz
40 MHz
Type 2
42 MHz
Type 3
30 MHz
Dimensions (W x H x D), Projections not included
Radio only
2-7/32 x 4-1/8 x 7/8 in. (56 x 105 x 21.9 mm)
with KNB-35L
2-7/32 x 4-1/8 x 1-5/32 in. (56 x 105 x 29.5 mm) 
with KNB-25A
2-7/32 x 4-1/8 x 1-3/8 in. (56 x 105 x 35.7 mm) 
with KNB-26N
2-7/32 x 4-1/8 x 1-3/8 in. (56 x 105 x 35.7 mm) 
Model
TK-2140
TK-3140
GENERAL Continued
Weight (net)
Radio only
5.99 oz. (170 g )antenna and belt hook
with KNB-35L
10.58 oz. (300 g )antenna and belt hook
with KNB-25A
12.7 oz. (360 g )antenna and belt hook
with KNB-26N
14.46 oz. (410 g )antenna and belt hook
FCC ID
Type 1
ALH32253110
ALH32263110
Type 1
ALH32263120
ALH32263120
Type 1
ALH32263130
ALH32263130
IC Certification
282196842A
282196837A
RECEIVER 
(Measurements made per EIA/TIA-204-D)
Sensitivity (12 dB SINAD)
Wide/Narrow
0.25µV/0.28µV
Selectivity
Wide/Narrow
70 dB/65 dB
70 dB/65 dB
Intermodulation Distortion
Wide/Narrow
70 dB/65 dB
70 dB/62 dB
Spurious Response 
70 dB
Audio Output
500 mW with less than 5% distortion
TRANSMITTER 
(Measurements made per EIA/TIA-603)
RF Power Output 
HI/LO
5 W/1 W
4 W/1 W
Spurious Response
70 dB
Modulation
Wide/Narrow
16KØF3E/11KØF3E
FM Noise
Wide/Narrow
45 dB/40 dB
Audio Distortion
Less than 3%
*+14°F ~ +140°F (-10°C ~ +60°C) when KNB-26N/35L in use
Options
Specifications
Applicable MIL-STD & IP
footnotes from Front:
1
Conventional Systems: 250 Channels; Trunked Systems: 600
repeater cCH.s max.; 250 GID max. per system/per radio
2
DTMF includes PTT ID, Emergency ANI, Auto-Dial (32 numbers) &
Stun (a.k.a. "deadbeat disable")
3
KPG-74D required: Windows
®
98/ NT/ 2000/ Me/XP compatible;
English screen language only.
4
Two-Tone Decode (3 sets x 2 pairs each); Operator Selectable
Tone (16 QT/DQT code pairs)
5
Kenwood LTR Features include: GID Delete/Add, LTR Talk Around/Scan
Revert Group Display, System Scan, Group Scan, Auto Search.
6
Short Text Messages are radio stored & LCD displayed.
Kenwood follows a policy of continuous advancement in development. 
For this reason specifications may be changed without notice.
FleetSync
®
is a registered trademark of Kenwood Corporation.
LTR
®
is a registered trademark of Transcrypt International. 
All other trademarks are property of their respective owners.
KNB-25A
Ni-Cd Battery Pack 
(1,200mAh)
KNB-26N
Ni-MH Battery Pack 
(2,000mAh)
KNB-35L
Li-ion Battery Pack 
(7.4V/1950mAh)
KNB-40LC
Li-ion Battery Pack 
(7.4V/1950mAh) I.S.
KBP-5
Battery Case
KSC-25
Rapid Charger
KSC-30
Charger for KNB-25A 
and KNB-26N
KRA-22
VHF Low Profile 
Helical Antenna
KRA-23
UHF Low Profile 
Helical Antenna
KRA-26
VHF Helical Antenna
KRA-27
UHF Whip Antenna
KMC-25
Speaker Microphone
KVC-3
Rapid Rate Vehicular 
Charger Adapter 
(for KSC-30)
KVC-4
Rapid Rate Vehicular 
Charger Adapter 
(for KSC-25)
KEP-1
Heavy Duty Earphone 
(Requires KMC-25)
KHS-11BL
2-wire Palm Mic with 
Earphone
KHS-12BL
3-wire Lapel Mic
with Earphone (Black)
KHS-14
Lightweight
Single Muff Headset
KLH-116
Hard Leather Case
w/Swivel
KBH-12
Belt Clip
KNB-35L
KSC-25
KVC-3
Standard
MIL 810C 
MIL 810D 
MIL 810E
MIL 810F 
Methods/Procedures
Methods/Procedures Methods/Procedures Methods/Procedures
Low Pressure
500.1/Procedure I
500.2/Procedure I, II
500.3/Procedure I, II
500.4/Procedure I, II
High Temperature
501.1/Procedure I, II
501.2/Procedure I, II
501.3/Procedure I, II
501.4/Procedure I, II
Low Temperature
502.1/Procedure I
502.2/Procedure I, II
502.3/Procedure I, II
502.4/Procedure I, II
Temperature Shock
503.1/Procedure I
503.2/Procedure I
503.3/Procedure I
503.4/Procedure I, II
Solar Radiation
505.1/Procedure I
505.2/Procedure I
505.3/Procedure I
505.4/Procedure I
Rain
506.1/Procedure I, II
506.2/Procedure I, II
506.3/Procedure I, II
506.4/Procedure I, III
Humidity
507.1/Procedure I, II
507.2/Procedure II, III
507.3/Procedure II, III
507.4
Salt Fog
509.1/Procedure I
509.2/Procedure I
509.3/Procedure I
509.4
Dust
510.1/Procedure I
510.2/Procedure I
510.3/Procedure I
510.4/Procedure I, III
Vibration
514.2/Procedure VIII, X
514.3/Procedure I
514.4/Procedure I
514.5/Procedure I
Shock
516.2/Procedure I, II, V
516.3/Procedure I, IV
516.4/Procedure I, IV
516.5/Procedure I, IV
International Protection Standard
Dust & Water Protection
IP54/55