Kenwood TK-860G Manual Do Utilizador

Página de 36
23
ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-860G/862G
1. Frequency
1) Set test mode
Power meter Rear
ANT
Front
CH /
Check
498.600MHz
±
100Hz K2
Select “FREQ” in tuning mode. F. counter panel
panel
502.600MHz
±
100Hz M2
PTT : ON
Adjust [_**]
2. Power
1) Maximum power
Check
More than 26.0W
output
Set test mode
Select “HPOW” in tuning mode.
“H.POW”
Adjust [256]
PTT : ON
3. High power
1) Set test mode
25.0W
±
1.0W
Select “HPOW” in tuning mode.
“H.POW”
PTT : ON
Adjust [***]
2) “H.P.OW”
PTT : ON
Adjust [***]
3) “H.P.O.W”
PTT : ON
Adjust [***]
4) “H.P.O.W.
PTT : ON
Adjust [***]
5) “H.P.O.W._.
25W K2
±
1.0W
PTT : ON
22W M2
Adjust [***]
4. Low power
1) Set test mode
Power meter
5.0W
±
0.5W
Select “LPOW” in tuning mode.
“L.POW”
PTT : ON
Adjust [***]
2) “L.P.OW”
PTT : ON
Adjust [***]
3) “L.P.O.W”
PTT : ON
Adjust [***]
4) “L.P.O.W.
PTT : ON
Adjust [***]
5) “L.P.O.W._.
PTT : ON
Adjust [***]
5. Power check 1) Set test mode
Power meter Rear
ANT
Check
25W
±
1W, 8A or less
CH : CH1 - Sig1
panel
 CH2 - Sig1
Ammeter
DC IN
 CH3 - Sig1
PTT : ON
Transmitter Section