Sterling 882.00294.00 Manual Do Utilizador

Página de 63
lower display indicates the High Point Setting alarm value.  The factory setting for the High 
Point Alarm Value 
(L1-hi )
 is 150
°F (-23°C). 
Restoring the WATLOW Redundant Safety Controller to Factory Setup 
If the preset parameters on the controller have been tampered with and it no longer functions 
properly, call the Service Department.   
Note:  This controller is not meant to be modified. 
WATLOW Operating Parameters 
The WATLOW controller has only one mode selection; ALARM. 
The factory has set the security level to protect the critical parameters from being accidentally 
changed. Below is an explanation of the modes you will have access to and the manufacturer 
default settings. 
Entering Operating Parameters to Select Modes 
To enter the display: 
 
1.  Press both the Up 
 and Down 
 keys for three seconds from the home page.  
The word SEE will appear in the upper display and PAGE will appear in the lower 
display. 
2.  Press the Advance Key  
 to move through the parameter prompts. 
3.  Press the Up 
 or Down 
 keys to change the parameter value. 
4.  Press the RESET Key at any time to return to the Home Page display. 
 
 
Figure 6:  Setting List for Redundant Safety Controller (WATLOW), Part No. A0568961 
Mode 
Parameter 
Setting range 
Default 
Manuf. 
setting 
SEn Sensor 
Type 
0-3 
Lin 
Thermocouple Linearization  0-10 
H (1) 
C-F 
Temperature Units 
Fahrenheit / Celsius 
S.dEC 
Temp. Decimal Places 
0 – 0.0 
IS.En 
INFOSENSE™ 
Yes / No 
No 
Sc.Lo 
Process Scale Low 
4.00 to 20.00 mA   
1.00 to 10.00V  
4.00 mA 
1.00V 
Sc.hi 
Process Scale High 
4.00 to 20.00 mA 
1.00 to 10.00V 
20.00 mA 
5.00 V 
400 
CAL Calibration 
Offset 
-999 to 999 
Ftr.E Input 
Filter 
Off, 
DiSP, Cont, both 
OFF 
Ot 1 
Output 1 Function 
Limit (2) 
(2) 
LSd1 
Output 1 Limit Sides 
Both, High, Low 
Both 
High 
hyS1 
Limit 1 Hysteresis 
0.0 to 999.0 
1.0 
Ot2 
Output 2 Function 
Off / Process Alarm / Limit (2)  
OFF 
LSd2 
Output 2 Sides 
Both / high / low 
Both 
Portable Drying/Conveying Systems 
Chapter 4:  Operation 
37 of 63