12
4. 
Connect neutral ground wire and  
neutral wire
C
E
B
6. 
Connect remaining wires
5. 
Connect ground wire
F
A
Connect ground wire (green or bare) (F) of direct wire cable 
to external ground conductor screw (A). Tighten screw.
Place hooked ends of remaining direct wire cable wires under 
outer terminal block screws (hooks facing right). Squeeze 
hooked ends together and tighten screws. Finally, reinsert tab 
of terminal block cover into slot of dryer rear panel. Secure  
cover with hold-down screw. Now, go to “Venting Requirements.” 
Connect neutral ground wire (E) and place hooked end (hook  
facing right) of neutral wire (white or center wire) (C) of direct 
wire cable under center screw of terminal block (B). Squeeze 
hooked ends together and tighten screw.
3-WIRE DIRECT WIRE 
CONNECTION
1. 
Prepare your 3-wire cable for  
direct connection
     1"
(25 mm)
    3½"
(89 mm)
3. 
Remove center screw
B
Use where local codes permit connecting  
cabinet-ground conductor to neutral wire. 
Remove center terminal block screw (B).
Direct wire cable must have 5 ft. (1.52 m) of extra length so 
dryer may be moved if needed.
Strip 3
1
/
2
" (89 mm) of outer covering from end of cable. Strip 
insulation back 1" (25 mm). If using 3-wire cable with ground 
wire, cut bare wire even with outer covering. Shape wire ends 
into hooks. 
2. 
  Attach hooked wires to terminal 
block
To connect wires to terminal block, place hooked end of 
wire under terminal block screw, facing to the right, squeeze 
hooked end together and tighten screw.