Whirlpool W10563341A Manual Do Utilizador

Página de 20
10
4-wire Direct Wire Connection
IMPORTANT: 
A 4-wire connection is required for mobile homes 
and where local codes do not permit 3-wire connections. 
2.
 
Prepare to connect neutral 
     ground wire and neutral wire
E
A
B
Remove center terminal block screw (B). Remove neutral 
ground wire (E) from external ground conductor screw (A).
Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer 
may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving 
bare ground wire at 5" (127 mm). Cut 1
1
/
2
" (38 mm) from 
remaining 3 wires. Strip insulation back 1" (25 mm). Shape ends 
of wires into hooks.
     1"
(25 mm)
       5"
(127 mm
)
1.
 
Prepare your 4-wire cable for  
     direct connection
3-wire Direct Wire Connection
IMPORTANT: Use where local codes permit connecting  
cabinet-ground conductor to neutral wire. 
4.
 
Connect ground wire
A
F
Connect ground wire (green or bare) (F) of direct wire cable 
to external ground conductor screw (A). Tighten screw.
Place hooked ends of remaining direct wire cable wires  
under outer terminal block screws (hooks facing right). 
Squeeze hooked ends together and tighten screws. Finally, 
reinsert tab of terminal block cover into slot of dryer rear 
panel. Secure cover with hold-down screw. Now, go to 
Venting Requirements. 
5.
 
Connect remaining wires
B
E
C
3.
 
Connect neutral ground wire  
      and neutral wire
Connect neutral ground wire (E) and place  
hooked end (hook facing right) of neutral wire (white or center 
wire) (C) of direct wire cable under center screw of terminal 
block (B). Squeeze hooked ends together and tighten screw.
Direct wire cable must have 5 ft. (1.52 m) of extra length so 
dryer may be moved if needed.
Strip 3
1
/
2
" (89 mm) of outer covering from end of cable. Strip 
insulation back 1" (25 mm). If using 3-wire cable with ground 
wire, cut bare wire even with outer covering. Shape wire ends 
into hooks. 
     1"
(25 mm)
    3½"
(89 mm)
1.
 
Prepare your 3-wire cable for  
     direct connection