Whirlpool W10300460A Manual Do Utilizador

Página de 16
10
3.  Place the hooked ends of the other direct wire cable wires 
under the outer terminal block screws (hooks facing right). 
Squeeze hooked ends together. Tighten screws.
4.  Tighten strain relief screw.
5.  Insert tab of terminal block cover into slot of dryer rear panel. 
Secure cover with hold-down screw.
6.  You have completed your electrical connection. Now go  
to “Venting Requirements.”
optional 3-wire connection
use for direct wire or power supply cord where local codes 
do not permit connecting cabinet-ground conductor to 
neutral wire. You must verify with a qualified electrician that 
this grounding method is acceptable before connecting.
1.  Remove center, silver-colored terminal block screw (B).
2.  Remove neutral ground wire (E) from external ground 
conductor screw (A).
A
E
B
 
3.  Connect neutral ground wire (E) and the neutral wire (C) (white 
or center wire) of power supply cord/cable under center, 
silver-colored terminal block screw (B). Tighten screw.
E
B
C
3-wire connection: Direct wire
use where local codes permit connecting cabinet-ground 
conductor to neutral wire.
Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer 
can be moved if needed.
Strip 3½" (89 mm) of outer covering from end of cable. Strip 
insulation back 1" (25 mm). If using 3-wire cable with ground 
wire, cut bare wire even with outer covering. Shape ends of wires 
into a hook shape.
     1"
(25 mm)
    3½"
(89 mm)
When connecting to the terminal block, place the hooked end of 
the wire under the screw of the terminal block (hook facing right), 
squeeze hooked end together and tighten screw, as shown.
1.  Loosen or remove center, silver-colored terminal block  
screw (B).
B
2.  Place the hooked end of the neutral wire (C) (white or center 
wire) of direct wire cable under the center, silver-colored 
terminal block screw (B) (hook facing right). Squeeze hooked 
end together. Tighten screw.
B
C