Whirlpool CEDC392JQ0 Manual Do Utilizador

Página de 16
6
Recommended/Minimum Clearances
Most installations require a minimum 5 in. (12.7 cm) clearance 
behind the dryer for the exhaust vent with elbows. See “Venting 
Requirements.”
NOTE:
 Observe all governing codes and ordinances.
†Height with casters is 32½” (82.6 cm).
Recessed Area and Closet Installation
Your dryer needs a certain amount of space around it for proper 
ventilation and for easier installation and servicing. The following 
minimum installation spacings are required when the unit is to be 
operated with, or without, the Stack Stand Kit. To purchase a 
Stack Stand Kit, see “Assistance or Service.” 
Minimum installation spacing
1. Side                                       4. Front—stack stand
2. Front                                      5. Side—stack stand
3. Closet door
*  Additional space may be needed for exhaust elbow
** Opening is minimum for closet door. Louvered
   door with air opening is acceptable.
*** May be 0” (0 cm) clearance
Additional spacing should be considered for ease of 
installation and servicing.
Additional clearances might be required for wall, door, and 
floor moldings.
Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is 
recommended to reduce noise transfer.
For closet installation with a door, minimum ventilation 
openings in the top and bottom of the door are required. 
Louvered doors with equivalent ventilation openings are 
acceptable.
Companion appliance spacing should also be considered.
NOTE:
 No fuel-burning appliances may be installed in the same 
closet as a dryer.
Mobile Home-Additional Location Requirements
This dryer is suitable for mobile home installations. Follow the 
information in “Location Requirements.” 
The installation must conform to the Manufactured Home 
Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile Home Construction 
and Safety, Title 245, HUD Part 280).
23
7
8
(60.6 cm)
"
20
3
4
(52.7 cm)
"
31"
(78.7 cm)