CONNECTING ELECTRIC DRYERS 
(cont.)
Remove 5 inches (12.7 cm) of the outer 
covering from the wire. Remove 5 inches 
of insulation from the ground wire. Cut off 
approximately 1
1
2
 inches (3.8 cm) from the 
other three wires and strip 1 inch (2.5 cm) 
insulation from each wire. Bend the ends of 
the three shorter wires into a hook shape.
1
Transfer the dryer’s ground wire from behind 
the green ground screw to the center screw 
of the terminal block. Attach the two hot 
leads of the power cable to the outer terminal 
block screws. Attach the white neutral wire 
to the center terminal block screw. Attach the 
power cable ground wire to the green ground 
screw. TIGHTEN ALL SCREWS SECURELY. 
Reinstall the terminal block access cover.
3
Ground Wire
Ground Screw
Neutral 
(White)
 Hot 
 (Black)
Ground Wire
Hot 
(Red)
Remove the terminal block access cover  
on the upper back of the dryer. Install a  
UL-listed strain relief into the power cord 
through-hole; then thread the power cable 
prepared in Step 1 through the strain relief.
2
UL-Listed 
Strain Relief
UL-Listed  
4-Wire  
Power Cord
Terminal 
Block
5"  
(12.7 cm)
1"  (2.5 cm)
Four-Wire Connection for Electric Dryers: Direct Wire
•  A 4-wire connection is required for all mobile 
and manufactured home installations, as well  
as all new construction after January 1, 1996. 
•  A UL-listed strain relief is required. 
•  Use UL-listed 
4-wire #10 AWG-minimum 
copper conductor cable.
•  Allow at least 5 ft (1.5 m) length to allow for 
removal and reinstallation of the dryer. 
w
WARNING: 
• Connect the power cord to the terminal block. Each colored wire should be connected  
to same color screw. Wire color indicated on manual is connected to the same color 
screw in block. Failure to follow these instructions may result in a short or overload.
• Grounding through the neutral conductor is prohibited for: (1) new branch-circuit  
installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local  
codes prohibit grounding through the neutral conductor.
USA ONLY
1