JAI 141MCL-RA Manual Do Utilizador

Página de 52
 
CM-141MCL/PMCL/RA / CB-141MCL/PMCL/-RA
 
 
 
28 
6.3.5   Smear less EPS Trigger mode 
This mode is EPS trigger mode with smear less function.  Once the external trigger is input, a 
fast dump is activated. Then exposure starts with the preset shutter speed.  
This mode can eliminate smear on the upper part of the image.  
 
This mode functions only in LVAL asynchronous mode. 
 
To use this mode:  
Set function: 
Trigger mode                    Smear less Edge PreSelect 
 
Scanning 
                 Full, Partial 
 
Vertical binning                   ON / OFF (CM-141MCL only) 
 
Shutter mode                       Preset, Programmable, Fine Exposure 
 
Shutter speed                      1/60 to 1/10,000 
 
 
Programmable exposure       2L to 1052 L   
 
Accumulation 
                  LVAL async only 
 
Other functions and settings 
Input: 
Ext. trigger.  
                  12-pin Hirose or Camera Link 
 
 
Important notes on using this mode
 
 
Trigger pulse >2 LVAL to < 
 
The following table shows minimum trigger interval in synchronous accumulation mode 
 
Full scan 
1268  L 
2/3 Partial 
989  L 
1/2 Partial 
 850 L 
1/4 Partial 
642 L 
1/8 Partial 
438 L 
1/2 V Binning 
744 L 
 
 
 
 
 
Fig.31   Smearless EPS mode timing 
Trigger
CCD
Exposure
EEN
FVAL
DVAL
211L
2L to 3L
Trigger Invalid Period
Smearless Period