Toshiba TLP848 Manual Do Utilizador

Página de 12
TLP848 
2007-10-01 
11
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Relative Positioning of Shutter and Device 
For normal operation, position the shutter and the device as shown in the figure below. By considering the 
device's detection direction characteristic and switching time, determine the shutter slit width and pitch.   
 
 
 
0
0.2
0.4
0.6
0.8
1
1.2
-2
-1
0
1
2
3
4
0
0.2
0.4
0.6
0.8
1
1.2
-1.2
-0.8
-0.4
0
0.4
0.8
1.2
Detection position 
characteristics (1)       (typ.)
Distance  d  (mm)
 
 
R
elat
ive c
ollect
or current
 
Detection position 
characteristics (2)       (typ.)
Distance  d  (mm)
 
 
R
elat
ive c
ollect
or current
 
IF = 5mA 
VCE = 2V 
Ta = 25°C 
 
 
 
 
 
 
 
Detection position
d = 0 ± 0.2mm 
Shutter 
+
− 
IF = 5mA 
VCE = 2V 
Ta = 25°C 
 
 
 
 
 
 
 
Detection position
d = 0.75            mm
Shutter 
+0.6 
-
0.5 
1.35 min 
0.75 
0.25 max 
Center of sensor 
Unit: mm
Cross section between A and A' 
A
A’
Shutter