VIVOTEK IP3122 Manual Do Utilizador

Página de 65
 
 
 
 
 
 
 
 
 
 
- 55 - 
 
 
 
 
  
www.vivotek.com 
 
 
 
 
 
General format of command URL 
Every configuration can be set through URL with POST method by the Administrator 
only. 
<general format> 
URL[?[name=value][&name=value]……] 
<method> 
POST 
<authorized user> 
root 
 
System configuration URL 
URL: /setup/system.cgi 
NAME VALUE 
DESCRIPTION 
host 
<text string shorter than 15 
characters> 
system name 
yes 
turn off front LED 
Ledoff 
no 
turn on front LED 
keep 
keep date and time unchanged 
auto 
use NTP server to synchronize 
method 
manu 
directly adjust date and time 
date 
<yyyy/mm/dd> 
year, month and date separated by 
slash 
time 
<hh:mm:ss> 
hour, minute and second separated 
by colon 
ntp 
<domain name or IP address> NTP server 
zone 
-12 ~ 12 
time zone, 8 means GMT +8:00