Canon PC900S Manual Do Utilizador

Página de 393
11-3
COPYRIGHT  ©  1999  CANON INC.                   CANON  PC800s/900s REV.0 AUG. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
I.
MAINTENANCE AND INSPECTION
A.
Image Adjustment Basic Procedure
Making Pre-Checks
Adjusting the Optimum Density
Clean the parts.
Is the copy density
 correction switch (SW101) set 
to the middle index? 
(Note 1)
Set it at 
the middle.
Select non-AE, and set the copy density 
adjusting lever to the middle index; then, 
make two to three copies of the Test 
Sheet (NA-3).
Check the following:
1.  Density of gray scale No. 9
2.  Presence/absence of difference between front 
and rear (Note 2)
3.  Density of gray scale No. 1 (good or bad; Note 2)
4.  Fogging of background (Note 2)
NO
YES
Scanning system, 
pickup/feeding system, 
delivery assembly
Check the following:
1. Cartridge
2. Scanning lamp
3. AE sensor PCB
4. DC controller PCB
5. Composite power supply PCB
 (See the appropriate troubleshooting 
procedure.)
Is the optimum 
density obtained by intensity 
adjustment? 
(Note 3)
Can the 
deviation be corrected 
using the copy density correction 
switch (SW101)? 
(Note 1)
Is gray scale No. 9 
barely visible?
END
YES
YES
YES
NO
NO
NO
Note:
1. Applies only if the machine is equipped with a copy 
density correction switch (SW101).
2. The machine is not equipped with a function to 
correct image faults. See the appropriate 
troubleshooting procedure.
3. See p. 11-42.