Casablanca Fan Company 89UXXM Manual Do Utilizador

Página de 15
13
SEND SIgNAL 
LED
Versa•Touch2 oPeraTion
Fan Control
To start the fan. Press the selected speed button to run the fan at the desired speed.
LO=Low speed    mED=medium speed     HI=High speed
To turn off the fan. Press the 
FAN OFF  button.
Airflow Direction
To reverse the airflow press the 
REVERSE button. Reverse operates at any speed whether fan 
is on or off. The fan returns to its set speed after reversing.
Light Control
Turn the light on or off independently from the fan by pressing the 
LIgHT button.  Keep 
pressing the button in excess of 0.7 seconds, it becomes a dimmer. The light varies from 
‘bright’ to ‘dim’ over approximately 8 seconds. This sequence will reverse the light when it 
reaches the brightest or dimmest level if you continue to hold the 
LIgHT button. Release 
the button when the desired level is reached.
memory Feature
The last light function and fan speed will resume when power is turned back on.
Auto Resume
Quick (pressing less than 0.7 seconds) on/off operation of the 
LIgHT button maintains the 
desired brightness level set previously.  
Versa•Touch2  IF FAN DOES NOT WORK
If the fan is not functioning after installation:
Step 1. Check to make sure that batteries are installed correctly 
in the control.
Step 2. Turn the power off to the fan (from the circuit breaker) 
for at least 5 seconds.
Step 3. Turn the power back on (at the circuit breaker) and push 
the Hi, Med, and Low buttons–in that order–within 20 seconds.
Step 4. The fan should now function properly.
Versa•Touch2  CHANgINg FREQUENCY SETTINg
you will only have to change the dip switch settings in the remote if 
you are using more than one fan in the same area and want to control 
them separately.
Step 1. At the circuit breaker or fuse box, turn the power off for the 
fan you want to change.
Step 2. Open the battery door of the Versa•Touch control and remove
the batteries.
Step 3. Change the dip switch settings, assuring that they are different 
from the previously installed Versa•Touch fan.
Step 4. Re-install the batteries and the battery door on the control.
Step 5. At the circuit breaker or fuse box, turn the power back on for 
the fan whose frequency you are changing.
Step 6. Within 20 seconds of restoring power, push the Hi, Med, and 
Lo buttons (in that order).
note: All fans leave the factory set to ‘00000’.
WITHIN 20 SECONDS OF 
TURNINg THE FAN ON, 
PRESS IN THIS ORDER TO 
SET NEW FREQUENCY:
 
1. HI
 
2. mED
 
3. LO
1
2
3
CIRCUIT BREAKER
OR FUSE BOX
PRESS IN THIS ORDER TO SET NEW 
FREQUENCY:
1. HI      2. mED      3. LO
DIP SWITCH
SET TO ‘01001’
DIP SWITCH
SET TO ‘10000’
Versa•Touch 2
CONTROL
(BACK)
note: You may want to label your controls to 
assure you do not mix them up.
WARNINg: Do not turn the power off at the circuit breaker, 
then  back  on,  for  the  previously  installed  Versa•Touch  2
fan(s), as you may inadvertantly change the frequency set-
tings for it as well.
LO
mED
HI
LIgHT
FAN
STOP
REVERSE
1
2
3
V
ersa
•T
ouch
2
®