Zebra Technologies radio frequency identification (rfid) Manual Do Utilizador

Página de 162
109
ZPL II Commands for RFID
^RS
11/14/2008
RFID Programming Guide
58978L-008 Rev. A
p
= read/write position of 
the transponder
Sets the read/write position of the transponder in vertical 
(Y axis) dot rows from the top of the label. Set to 0 (no 
movement) if the transponder is already in the effective area 
without moving the media.
Important • 
If a label format specifies a value for this 
parameter, this value will be used for the programming 
position for all labels until a new position is specified 
or until the printer is turned off (O) and then back 
on (I).
Accepted values: 0 to label length
Default value: 
For the R110PAX4 and R2844-Z: 0
For all other supported printers: label length minus 
1 mm (1/16 in.)
v
= length of void 
printout
Sets the length of the void printout in vertical (Y axis) dot 
rows.
Accepted values: 0 to label length
Default value: label length
n
= number of labels
The number of labels that will be attempted in case of 
read/encode failure.
Accepted values: 1 to 10
Default value: 3
e
= error handling
If an error persists after the specified number of labels are 
tried, perform this error handling action.
Accepted values:
N =
No action (printer drops the label format causing 
the error and moves to the next queued label)
P = 
Place printer in Pause mode (label format stays in 
the queue until the user cancels)
E = 
Place printer in Error mode (label format stays in 
the queue until the user cancels)
Default value: N
Note • 
You can set the printer to send an error 
message to the host for each failure. To enable or 
disable this unsolicited error message, refer to the 
^SX
 and 
^SQ
 ZPL commands. Use 
V
 for the 
condition type for an RFID error.
Parameters
Details