Zebra Technologies radio frequency identification (rfid) Manual Do Utilizador
109
ZPL II Commands for RFID
^RS
11/14/2008
RFID Programming Guide
58978L-008 Rev. A
p
= read/write position of
the transponder
Sets the read/write position of the transponder in vertical
(Y axis) dot rows from the top of the label. Set to 0 (no
movement) if the transponder is already in the effective area
without moving the media.
(Y axis) dot rows from the top of the label. Set to 0 (no
movement) if the transponder is already in the effective area
without moving the media.
Important •
If a label format specifies a value for this
parameter, this value will be used for the programming
position for all labels until a new position is specified
or until the printer is turned off (O) and then back
on (I).
position for all labels until a new position is specified
or until the printer is turned off (O) and then back
on (I).
Accepted values: 0 to label length
Default value:
For the R110PAX4 and R2844-Z: 0
For all other supported printers: label length minus
1 mm (1/16 in.)
1 mm (1/16 in.)
v
= length of void
printout
Sets the length of the void printout in vertical (Y axis) dot
rows.
rows.
Accepted values: 0 to label length
Default value: label length
n
= number of labels
The number of labels that will be attempted in case of
read/encode failure.
read/encode failure.
Accepted values: 1 to 10
Default value: 3
e
= error handling
If an error persists after the specified number of labels are
tried, perform this error handling action.
tried, perform this error handling action.
Accepted values:
N =
No action (printer drops the label format causing
the error and moves to the next queued label)
the error and moves to the next queued label)
P =
Place printer in Pause mode (label format stays in
the queue until the user cancels)
the queue until the user cancels)
E =
Place printer in Error mode (label format stays in
the queue until the user cancels)
the queue until the user cancels)
Default value: N
Note •
You can set the printer to send an error
message to the host for each failure. To enable or
disable this unsolicited error message, refer to the
disable this unsolicited error message, refer to the
^SX
and
^SQ
ZPL commands. Use
V
for the
condition type for an RFID error.
Parameters
Details