SGD Commands for RFID
rfid.reader_1.power.write
11/14/2008
RFID Programming Guide
58978L-008 Rev. A
rfid.reader_1.power.write
Description  This command sets or gets the RFID reader power level for writing to RFID 
tags.
Type  getvar; setvar
This table identifies the command for this format:
Note • 
This parameter is ignored on the R110Xi HF printer because read and write powers 
cannot be specified separately. See rfid.reader_1.power.single_power
 to set the 
power level for the R110Xi HF printer.
Commands
Details
getvar
This command instructs the printer to respond with the reader’s current 
write power level. 
Format: ! U1 getvar "rfid.reader_1.power.write" 
setvar
This command instructs the printer to set the write power level on the 
RFID reader. 
Format: ! U1 setvar "rfid.reader_1.power.write" 
"value"
 
Note • 
On some printers, the options vary based on the reader. 
Check the printer configuration label for the RFID_HW_VER line 
or perform the 
RFID SLOW test (see 
to determine the reader type.
Printer
Firmware Version
Selections
Default
high, 
medium, 
low
0–30
up, 
down
RXi
R60.15.8Z and earlier
X
low
R60.16.4Z
X
X
low
R60.16.5Z and later (M4xxx…x reader)
X
X
low
R60.16.5Z and later (M5xxx…x reader)
X
X
16
R4Mplus
SP994P, SP999F, SP1027F, SP1056E, 
SP1082F,  and earlier
X
low
SP994Q, SP999G, SP1027G, SP1056F, 
SP1082G,  and later
X
X
low
R110PAX4
R62.15.8Z and earlier
X
low
R62.16.4Z and later
X
X
low
R63.15.8Z and earlier
X
low
R63.16.4Z and later
X
X
low
RZx00
all versions
X
X
16
RP4T
all versions
X
X
16