Toshiba CTX28 Manual Do Utilizador

Página de 495
T1
T1
RDTU1 & 2 - T1 Interface Unit
Strata CTX I&M        06/04
8-15
RDTU1 & 2 - T1 Interface Unit
Circuits per PCB:
8, 16, or 24 channels
Interfaces with:
ground start CO lines
loop start CO lines
DID or Tie lines
Older Version(s): 
none
RDTU is configured for Tie or DID lines and an RRCS must be installed for DTMF operation. 
LEDs on the RDTU show a continuous status of RDTU operation. The Strata CTX can support up 
to eight RDTU2 or RPTU2 PCBs total. 
RDTU controls and interface connectors are shown in 
 and described in 
The RDTU requires installation of a customer-provided Channel Service Unit (CSU). Refer to 
 for CSU installation.
Testing procedures (local loop back and remote loop back) are in 
.
SW1 Equalizer Switch and Loop Back Jumpers (Internal Option)
The distance between the Strata CTX cabinets and the CSU (or other customer premise T1 circuit) 
determines the setting of the SW1 Equalizer Switch. The SW1 switch consists of a bank of smaller 
switches, S1~S7.
³
Set the SW1 switch per 
Note
The maximum distance between the RDTU and the CSU or other T1 circuits can not be 
more than 655 feet (see “RDTU to PBX T1 (Separated More Than 655 ft.)” on 
).
RDTU1 & 2 Installation
1. Set jumper wire plugs P1 (LB), P2, P3, and P4 to the Off position. See 
 for loop back testing procedures.
See 
 for the 
appropriate SW1 equalizer switch setting.
2. Insert the RDTU (component side facing right) into the appropriate slot and apply firm, even 
pressure to ensure proper mating of connectors. (See 
 for RDTU slot assignment recommendations.) (See 
.)
Table 8-11
RDTU1 & 2 Equalizer Switch and Loop Back Jumpers
Mode
Feet from Strata 
CTX
S1
S2
S3
S4
S5
S6
S7
S8
Short
0~150
On
Off
Off
Off
Off
Off
Off
N/A
Medium
151~450
Off
On
Off
On
Off
On
Off
N/A
Long
450~655
Off
Off
On
Off
On
Off
On
N/A