Toshiba CTX28 Manual Do Utilizador

Página de 495
Peripheral Installation
External Page with BIOU Interface
12-10
Strata CTX I&M        06/04
External Page with BIOU Interface
Up to two BIOU interfaces can be installed for connecting external page equipment. Each BIOU 
can provide up to four unique page zones for a total of eight page zones maximum per system. The 
BIOU interfaces can be installed in the main cabinets and/or any remote cabinet. Each BIOU 
provides a 600ohm, non-amplified page output and an 8 ohm, 3-watt amplified page output. Only 
one type of page output, amplified or non-amplified, can selected per BIOU in a given installation. 
The BIOU also provides a control relay which can be used to mute external BGM when the 
external page circuit is active (see 
~
 for connection diagrams).
Figure 12-9
Single Zone Page Options
A separate external BGM source can be connected to a building’s external Page speakers using the 
BIOU interface. This enables the BGM sent over the external page speakers to be different from 
the BGM sent to telephone speakers (see 
) for separate BGM over external Page 
connections). 
Figure 12-10 Separate BGM Over External Page
SW600 (Select SPO or SP1)
System
      Back Plane
5605
BIOU (1 or 2)
SPTO   38, BK-GN
SPRO   13, GN-BK
Jacketed
Twisted Pair
24 AWG
66 Block Wiring
Page, BGM
or Night Ringing
switched in by 
System Processor
HESB
or
External
Amplifier
and Speaker
(8ohm minimum)
HESB
or
External
Speaker
 600
Ω
Transformer
SPT1   50, V-S
SPR1   25, S-V
SPO
SP1
Level Control
3 Watt Amplifier
SP
BGM Mute Relay
2
1
Night Ring
and Page
from KSU 
Backplane
600
Ω
SPT (38)
BK-GN
GN-BK
Input 1
Output
External
Paging Amp
M
BGM
Music
Source
Mute 2
Input 2
B
BIOU (1 on 2)
SPR (13)
MDF
5601