Replacement
Motion Sensor
Requirements
•  The light control requires 120-volts AC.
•  If you want to use Manual Mode, the control must
be wired through a switch.
Some codes require installation by a qualified 
electrician.
© 2007 HeathCo LLC
595-5544-06
Features
•  Turns on lighting when motion is detected.
•  Automatically turns lighting off.
•  Photocell keeps the lighting off during daylight
hours.
•  LED  indicates  motion  was  sensed  (day  or
night).
Model SL-5407
OPERATION
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
1
/
2
minutes
for the circuitry to calibrate.
ON-TIME
10 5 1 TEST
10 5 1
TEST
ON-TIME
... back on.
1 Second OFF
then...
Put the ON-TIME switch in the 1,
5, or 10 minute position.
Put the ON-TIME switch on the
bottom of the sensor in the TEST
position.
Manual mode only works at night
because daylight returns the sen-
sor to AUTO.
Flip  the  light  switch  off  for  one
second  then  back  on  to  toggle
between  AUTO  and  MANUAL
MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Move ON-TIME Switch to 
1, 5, or 10 minutes
Mode Switching Summary
Flip light switch 
off for one second 
then back on*
MANUAL MODE
AUTO
TEST
*  If you get confused while switching modes, turn
the power off for one minute, then back on. After
the calibration time the control will be in the AUTO
mode.
TEST
AUTO
MANUAL MODE
Mode:
On-Time
Works: Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 10 Minutes
x
Manual
To Dawn*
x