About Wireless Expansion
The VISTA-10SE supports up to 16 wireless zones that may be used exclusively or in
addition to hardwired zones 1 through 6.
The receiver detects signals from wireless transmitters within a nominal range of 200 feet.
The following 5881 Receivers may be used with this system (5882 in Canada), and each
supports the number of zones shown:
RF Receiver
No. of Zones
5881L/5882L
up to 8
5881M/5882M
up to 16
5881H/5882H
up to 16
UL
Wireless may not be used in UL Commercial Burglary installations.
In Canada, 5800 systems must use 5882 Series receivers. Information relative to the 5881
Series of receivers applies as well to the 5882 Series. 5881 and 5882 Series receivers can
support  the same 5800 type transmitters.
Any zone 
number from 10–25 can be used as a 5800 Series wireless zone (do not confuse this
with the number of zones that can be used, which is shown in table above).
Receiver Supervision
The receiver is supervised. The following conditions cause a Trouble report to be generated
and CHECK and ZONE 09 messages to be displayed:
 
Communication between the panel and the receiver is interrupted.
or
 
No valid RF signals from at least one supervised wireless transmitter are received within
12 hours.
House Identification
If you are using a 5804BD, 5827, or 5827BD Wireless Keypad with the system, you must
program a House ID Code (01-31) in field 
24 to establish proper communication. The keypad
must be set to the same ID.