Avaya 03-300430 Manual Do Utilizador
DTMR-PT (Dual-Tone Multifrequency Receiver Port)
Issue 1 June 2005
1119
Tone Detector Audit/Update Test (#43)
The DTMR port is refreshed with all time-slot information, and sanity audit is performed on the
DTMR port.
DTMR port.
Table 381: Test #43 Tone Detector Audit/Update Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
None
ABRT
The system was not able to allocate all the resources needed for this test.
1. Wait 1 minute and try again.
2000
ABRT
Response to the test request was not received within the allowable time
period.
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Hardware audit failed.
1. Run the short test sequence: test port location sh r 1.
2. If the problem persists, the system is still operating properly but system
2. If the problem persists, the system is still operating properly but system
capacity will be reduced. In order to restore the system performance to
normal, replace the Tone Detector or IPSI circuit pack containing the
defective DTMR port.
normal, replace the Tone Detector or IPSI circuit pack containing the
defective DTMR port.
PASS
The DTMR port has been successfully refreshed with its translation.