Avaya 03-300430 Manual Do Utilizador

Página de 2574
Communication Manager Maintenance-Object Repair Procedures
1894 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Error Log Entries and Test to Clear Value
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 1: SCOTCH Synchronous Loop-around test (#1275) failed.
1. Test the port (test port location long).
2. See 
on page 1898 for repair 
procedures.
c. Error Type 257: C-LAN port detected overrun or underrun condition that may indicate a 
hardware problem.
1. Test for hardware problem (test port location long).
Table 691: PPP-PT Error Log Entries 
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0 (
0
Any
Any
Any
test port location s
1 (
0
SCOTCH Sync 
Loop- Around 
(#1275)
MIN
ON
test port location l r 3
257 (
0
WRN
OFF
513 (
)
0
MIN
OFF
769 (
)
0
WRN
OFF
1281 (
)
0
1537-8 (
See
note
Session Status 
test (#1286)
MIN
OFF
1793–
1920 (
)
See
note
2305–
2816 (
See
note
3329 (
35768
TCP/IP Ping test 
(#1281)
WRN
OFF
3585 (
)
0, 1
TDM Loop-Around 
(#1285)
MAJ
ON
test port location l r 3