1904 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1125
ABRT
PPP Link is not in service.
1. Verify whether PPP link is in-service (status port location or 
status link n).
2. If the PPP link is not in service, release the link (release link n or 
release port location).
3. Repeat the test.
2100
ABRT
Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
PPP link is down.
1. Test the port (test port location long) to verify the SCOTCH 
Synchronous Local Loop Around test (#1275) result.
2. If the test passes, wait for sessions to come up.
3. If the test fails, check the destination and other components in the 
path (e.g., DS1 trunks).
4. If the destination and other components in the path are in-service and 
the test still fails, execute busyout port location and release 
port location
, and repeat the test.
5. If the test still fails, reset the circuit pack (busyout board 
locationreset board location, and release board 
location
). Repeat the test.
6. If the problem persists, replace the circuit pack.
PASS
PPP link is up.
Table 696: Test #1279 PPP Link Status Inquiry Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2