Avaya 03-300430 Manual Do Utilizador
SNC-BD (Switch Node Clock Circuit Pack)
Issue 1 June 2005
2027
2301
ABRT
The software timer could not be set before sending the downlink message
necessary to run this test.
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2306
ABRT
None of the circuit packs in this switch node carrier are responding to the
processor route messages sent by software.
processor route messages sent by software.
1. Run test led switch-node for the switch node where this switch
node carrier resides to verify whether the LEDs on any of the boards
light.
light.
2. If none of the LEDs light for the boards in this carrier, fix any problems
associated with the connectivity of this carrier to the server.
a. Use list fiber link to obtain a list of the fiber connections to
this carrier.
b. Check the LEDs on every SNI and EI, and fix any fiber problems.
c. Enter display errors, and follow the repair procedures for any
EXP-INTF error entries associated with the controlling IPSI
connected PN.
connected PN.
d. Follow the repair procedures for any SYNC, SNI-BD, SNC-BD,
FIBER-LK, or SNI-PEER error entries.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
Table 740: TEST #760 Processor Route Audit Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 3