Avaya 03-300430 Manual Do Utilizador

Página de 2574
VC-DSPPT
Issue 1 June 2005
2521
 
VC Port Reset DSP Test (#1106)
This test is destructive.
This test resets the VC-DSPPT and the DSP associated with it. As part of the reset procedure, 
the VC-DSPPT will execute a series of self-tests on the hardware. If these self-tests fail, the test 
will fail; otherwise the test will pass.
Before executing the test, the VC-DSPPT must be busied out by executing busyout port 
location
. After the completion of the test, the VC-DSPPT must be released by executing 
release port location.
Table 895: Test #1106 VC Port Reset DSP Test
Error
Code
Test
Result
Description / Recommendation
1000
ABRT
System resources required to run this test are not available, or the port may 
be busy with a call.
1. Retry the command at 1-minute intervals up to 5 times.
1015
ABRT
The VC-DSPPT is not busied out.
1. Busyout the VC-DSPPT by executing busyout port location
then retry the test.
2000
ABRT
Response to the test was not received from the VC-DSPPT within the 
allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2. If this result occurs again, replace the circuit pack.
2012
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The reset of the VC-DSPPT was unsuccessful.
1. Replace circuit pack.
PASS
The VC-DSPPT was successfully reset.
1. Release the VC-DSPPT by executing release port location.