Avaya 03-300430 Manual Do Utilizador

Página de 2574
Communication Manager Maintenance-Object Repair Procedures
806 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Congestion Query Test (#600)
This nondestructive test queries the number of used buffers to determine whether the C-LAN 
circuit pack is congested.
Normal call handling resumes when the C-LAN circuit pack has recovered from congestion.
FAIL
Circuit pack has detected a failure of Packet Interface Test #598.
1. Retry command at 1-minute intervals up to 5 times.
2. If the problem persists, reset the circuit pack with reset board 
location.
3. If the test continues to fail, replace the circuit pack.
PASS
Packet Interface Test #598 passed.
Table 275: Test #598 Packet Interface Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2
If:
Then:
Used buffers are, or are nearly, exhausted The test fails
The test fails
The switch redirects outgoing calls to another 
available C-LAN, and denies new incoming calls
Table 276: Test #600 Congestion Query Test 
Error 
Code
Test 
Result
Description / Recommendation
2000
ABRT
Did not receive circuit pack test response within the allowable time period.
1. Retry command at 1-minute intervals up to 5 times.
2. If the problem persists, reset the circuit pack with reset board 
location.
3. If the problem persists, replace the circuit pack.
 1 of 2