DS1-BD (DS1 Interface Circuit Pack)
Issue 1 June 2005
989
 
NPE Connection Audit Test (#50):
The system sends a message to the on-board microprocessor to update the network 
connectivity translation for all the Network Processing Elements (NPEs) on the circuit pack.
Table 340: Test #50 NPE Connection Audit Test 
Error 
Code
Test 
Result
Description / Recommendation
None,
2100
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1019
ABRT
Test already in progress.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
The circuit pack’s NPEs have been updated with their translation.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted, an 
incorrect board is inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Use add ds1 
location to administer the DS1 interface if it is not already 
administered.
2. If board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If so, the board was shut 
down. Reseating the board will re-initialize it.
3. Enter busyout board
4. Enter reset board
5. Enter release board
6. Enter test board long
This should re-establish the linkage between the internal ID and the 
port.