ICP-CC488 | Installation Guide | 3.0  
System Operations 
EN | 15 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
To arm the system in STAY Mode 1 (method 
one): 
1.  Enter your code and press [STAY]. 
2.  Two beeps sound and the STAY indicator is lit. 
Exit Time starts. 
The indicators for any zones that are programmed to 
be automatically isolated in STAY Mode 1 begin to 
flash until Exit Time expires. At the end of Exit 
Time, the zone indicators are extinguished and the 
codepad sounds one short beep. 
To arm the system in STAY Mode 1 (method 
two): 
1.  Press and hold [STAY]. 
2.  When two beeps sound, release the button. 
The STAY indicator is lit and Exit Time starts. 
The indicators for any zones that are programmed to 
be automatically isolated in STAY Mode 1 flash until 
Exit Time expires. At the end of Exit Time, the zone 
indicators are extinguished and the codepad sounds 
one short beep. 
If a zone is not sealed at the end of Exit Time, the 
zone is automatically isolated and is lit constantly on 
the remote codepad. The zone becomes an active 
part of the system again as soon as it is resealed. For 
example, if a window is open when Exit Time 
expires, the window does not become an active part 
of the system until it is closed. Opening the window 
after Exit Time expires causes an alarm. 
Forced Arming 
Arming the system when a zone is not sealed is 
known as forced arming. Refer to Section 14.3.7 Zone 
Options 2
 on page 63 to enable forced arming for 
each zone. 
If the STAY indicator does not light and a long beep 
sounds when you attempt to arm the system in STAY 
Mode 1, forced arming is not permitted. If this is the 
case, you must seal all zones or manually isolate 
them before you can arm the system. 
3.4 
Disarming the System from STAY 
Mode 1 
There are two methods to disarm the system from 
STAY Mode 1. You can always use the first method. 
You can use method two only if Option 4 is enabled 
in Location 497 (refer to Section 18.6 Consumer 
Options 2 
on page 83). 
To disarm the system from STAY Mode 1 
(method one): 
1.  Enter your code and press [STAY]. 
2.  Two beeps sound and the STAY indicator is 
extinguished. The system is now disarmed. 
 
 
 
To disarm the system from STAY Mode 1 
(method two): 
A flashing zone indicator represents a previous alarm 
in that zone. If this is the case, a valid User Code is 
required to disarm the system using method one. To 
enable method two, Option 4 in Location 497 must 
be enabled (refer to Section 18.6 Consumer Options 2 on 
page 83). 
1.  Press and hold [STAY]. 
2.  When two beeps sound, release the button. 
The STAY indicator is extinguished and the 
system is disarmed. 
 
Single button disarming from STAY 
Mode 1 reports as User Code 16. 
3.5 
Arming The System in STAY Mode 
STAY Mode 2 is used when you need to arm the 
perimeter and unused areas of the premises to detect 
a would-be intruder from entering the premises, 
while at the same time being able to move freely 
within an area that is automatically isolated.   
You can program zones to be automatically isolated 
in STAY Mode 2 using an Installer Code function 
(refer to Section 5.1.5) or a Master Code function 
(Section 5.2.6). 
If the system reports to a base station, it sends a 
Partial Close Report (Contact ID Event Code 456). 
Entry Guard Timer for STAY Mode 
When arming the system in STAY Mode 2, an 
optional entry timer called Entry Guard Timer for 
STAY Mode can be used to delay the sirens, strobe, 
and bell outputs if a zone that is not automatically 
isolated activates an alarm. Entry Guard Timer for 
STAY Mode is the delay time used for all zones, 
except 24-Hour zones, when the system is armed in 
STAY Mode 1 or STAY Mode 2.  
If the Entry Guard Timer for STAY Mode is 
programmed and a zone that was not automatically 
isolated is activated, the codepad beeps twice per sec 
until the Entry Guard Timer for STAY Mode expires 
or the system is disarmed. If the alarm is not reset 
before Entry Guard Timer for STAY Mode expires, 
the strobe, bell, and siren outputs are activated into 
alarm. 
 
Single button disarming from STAY 
Mode 2 reports as User Code 16. 
To arm the system in STAY Mode 2: 
1.  Press and hold [0]. 
2.  When two beeps sound, release the button. 
The STAY indicator is lit and the Exit Time 
starts.