Bosch ICP-CC404 Manual Do Utilizador

Página de 98
ICP-CC404 | Installation Guide | 20.0   Terminals and Descriptions 
 
 
80 Bosch 
Security 
Systems, 
Inc. | 12/08 | F01U089401-02
 
Table 65: 
(continued) 
 
Term 
Description 
master code 
A numeric code used for arming and disarming the system, and for allowing access to 
all functions available through the codepad. 
monitoring station 
A secure location where a digital receiver monitors a number of alarm systems and 
deciphers their alarm transmission reports so the operator can advise the appropriate 
authorities to take immediate action. 
panic 
A condition or type of alarm in which the user requires either immediate police or 
medical assistance. 
phone controller 
A device used to arm a security system over the telephone line, and to acknowledge 
domestic alarm reports. 
remote radio user 
code 
A code used to arm and disarm a system from a remote location, using hand-held 
transmitters (in AWAY Mode or STAY Mode 1). Remote panic alarms are also allowed. 
sealed 
Refers to a zone’s status. If a zone is sealed, the detection devices are not violated and 
the zone indicator is not lit (that is, a reed switch is closed or a detector is on standby 
waiting for an intrusion). 
sensor watch 
A feature that allows the control panel to recognize when detection devices might have 
stopped working. Sensor watch monitors the operation of a zone over a programmed 
time period. 
silent alarm 
An alarm that sounds only at a remote location, and gives no obvious local indication 
that an alarm was sent out. 
STAY Mode 1 
A condition that automatically isolates certain zones when the security system is armed 
in this mode. Only the installer can program these zones. 
STAY Mode 2 
A condition that automatically isolates certain zones when the security system is armed 
in this mode. The Master Code holder can program these zones. 
telco arming 
sequence 
A feature that automatically diverts a telephone number to another telephone when a 
security system is armed in AWAY Mode, the same as using call forwarding. 
telco disarming 
sequence 
An automatic suspension of diverting of the telephone when the system is disarmed. 
unsealed 
Refers to a zone’s status. If a zone is unsealed, the detection devices are violated and 
the zone indicator is lit (that is, a reed switch is open or a detector noted an intrusion). 
user code 
A numeric code used to arm and disarm the system. 
zone 
A monitored input used to activate an alarm. A zone might be set up to activate an 
alarm only when the system is armed or to operate whether the system is armed or 
disarmed.