BEA XL-DR Manual Do Utilizador

Página de 7
75.5268.01 20070111 
 
Page 2 of 7
 
 
 
 
• Loosen the retaining nut until the cable slides easily into 
the grommet ; 
• Partially unscrew the 2 front cover screws ; 
• Pull out the front cover with the 2 front cover screws. 
 
• Connect the quick disconnect terminal block to the main electronic 
circuit ; 
• Slide the main electronic circuit into the 2 housing slot guides and 
pull the main cable gently at the same time ; 
• Gently push the front cover and make sure that the external 
housing is properly seated (front cover must be flush with housing). 
• Screw the 2 front cover screws and tighten the retaining nut.
 
 
 
 
 
•  Check that both locking 
collars are at the same 
position 
•  Align the bracket slot to the 
locking collar guide as shown 
 
 
 
 
BROWN-GREEN   Power supply 
YELLOW                COM 1 
WHITE                    NC 1 
PINK                       NO 1 
BLACK                   COM 2 
RED                        NC 2 
BLUE                      NO 2
 
 
To insert or to remove the cable: 
 
•  Unscrew the retaining nut 
•  Pass the cable through the 
retaining nut and the grommet 
•  Screw the retaining nut 
 
 
Ceiling mounting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Wall mounting 
 
 
Note: The bold-type values give the minimum distance required to be able to fully adjust the sensor.
 
 
OPENING AND 
CLOSING THE 
SENSOR 
 
BRACKET 
MOUNTING  
 
 
WIRING 
 
 
SENSOR 
DIMENSIONS 
AND MOUNTING 
Bracket dimensions 
  
2.5 in
 
5 in
 
6.25 in
 
6.
5 i
n
 
6 i
n
 
   
3 in 
5.5 in 
6 in 
5 in
6.25 in