Desa Tech CRL3124PA/NA Manual Do Utilizador

Página de 36
www.desatech.com
113097-01L
5
Figure 1 - Vent-Free Gas Log Heater
(Logs May Vary by Model, Seasonal Oak Single Burner Model Shown)
Base Grate 
Log Set
Control Knob
Burner
Piezo 
Ignitor
PRODUCT IDENTIFICATION
State  of  Massachusetts:  The  installa-
tion must be made by a licensed plumber 
or  gas  fitter  in  the  Commonwealth  of 
Massachusetts.
Sellers  of  unvented  propane  or  natural 
gas-fired supplemental room heaters shall 
provide to each purchaser a copy of 527 
CMR 30 upon sale of the unit.
Vent-free  gas  products  are  prohibited  for 
bedroom and bathroom installation in the 
Commonwealth of Massachusetts.
LOCAL CODES
Install  and  use  heater  with  care.  Follow  all 
local  codes. In the absence  of local  codes, 
use  the  latest  edition  of  The  National  Fuel 
Gas Code, ANSI Z223.1/NFPA 54*
.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY  10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA  02269
Note: Where listed vented decorative logs are re-
quired, thermostat operation is not permitted.
UNPACkING
 CAUTION: Do not remove the 
data  plates  from  the  grate  as-
sembly. The data plates contain 
important product information.
1.  Remove logs and heater base assembly 
from carton. Note: Do not pick up heater 
base  assembly  by  burners.  This  could 
damage heater. Always handle base as-
sembly by grate.
2.  Remove all protective packaging applied 
to logs and heater for shipment.
3.  Check heater for any shipping damage. 
If heater is damaged call DESA Heating, 
LLC at 1-866-672-6040 for replacement 
parts before returning to dealer.
PRODUCT FEATURES
OPERATION
This heater is clean burning. It requires no outside 
venting. There is no heat loss out a vent or up a 
chimney. Heat is generated by realistic dancing, 
yellow flames. This heater is designed for vent-
free operation with flue damper closed. It has been 
tested and approved to ANSI Z21.11.2 standard 
for unvented heaters. State and local codes in 
some areas prohibit the use of vent-free heaters. 
This heater may also be operated as a vented 
decorative (ANSI Z21.60) product by opening the 
flue damper (non-thermostat operation only).
SAFETY PILOT
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The 
ODS/pilot is a required feature for vent-free 
room  heaters.  The  ODS/pilot  shuts  off  the 
heater if there is not enough fresh air.
PIEzO IGNITION SYSTEM
This heater has a piezo ignitor. This system re-
quires no matches, batteries or other sources 
to light heater.