Desa VGL30PRA Manual Do Utilizador

Página de 32
www.desatech.com
112882-01D
27
 WARNING: If you smell gas
•  Shut off gas supply.
•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone in your 
building.
•  Immediately call your gas supplier from a neighbor’s phone. Fol-
low the gas supplier’s instructions.
•  If you cannot reach your gas supplier, call the fire department.
IMPORTANT: 
Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, 
paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These 
POSSIBLE CAUSE
1. Metal expanding while heating 
or contracting while cooling
1. Heater burning vapors from 
paint, hair spray, glues, clean-
ers,  chemicals,  new  carpet, 
etc. (See IMPORTANT state-
ment above)
2. Gas  leak.  See  Warning 
statement above
1. Not  enough  fresh  air  is 
available
2. Low line pressure
3. ODS/pilot  is  partially 
clogged
1. Gas  leak.  See  Warning 
statement above
2. Control valve defective
1. Foreign matter between con-
trol valve and burner
2. Gas  leak.  See  Warning 
statement above
OBSERVED PROBLEM
Heater  produces  a  clicking/tick-
ing noise just after burner is lit or 
shut off
Heater produces unwanted odors
Heater  shuts  off  in  use  (ODS 
operates)
Gas odor even when control knob 
is in OFF position
Gas odor during combustion
REMEDY
1. This is common with most heat-
ers. If noise is excessive, contact 
qualified service person
1. Open  window  and  ventilate 
room. Stop using odor causing 
products while heater is running
2. Locate  and  correct  all  leaks 
(see  Checking  Gas  Connec-
tions, page 15)
1. Open window and/or door for 
ventilation
2. Contact local natural or pro-
pane/LP gas company
3. Clean ODS/pilot (see Cleaning 
and Maintenance, page 23)
1. Locate  and  correct  all  leaks 
(see  Checking  Gas  Connec-
tions, page 15)
2. Replace control valve
1. Take  apart  gas  tubing  and 
remove foreign matter
2. Locate  and  correct  all  leaks 
(see  Checking  Gas  Connec-
tions, page 15)
TROUBLESHOOTING
Continued