Desa CGD3924NR Manual Do Utilizador

Página de 32
12
103343
14"
Min.
Combustible 
Material 
Non-Combustible Material 
Hearth
5"
Min.
Combustible 
Material 
Minimum Non-
Combustible 
Material 
8"
Min.
12"
15"
18"
All minimum 
distances are
in inches
Log Set
18", 24", 30"
Models 
20"
1
/2
"
6"
8"
10"
12"
Distances to 
Underside of
Mantel 
Hood
(GA6050, GA6052)
Top of Fireplace
Opening
Underside of
Mantel Shelf
Mantel Shelf
INSTALLING
Continued
Floor Clearances
A. If installing appliance on the floor level, you must maintain the minimum
distance of 14" to combustibles (see Figure 8).
B. If combustible materials are less than 14" to the fireplace, you must install
appliance at least 5" above the combustible flooring (see Figure 9).
Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring
If your installation does not meet the above minimum clearances, you must:
• operate the logs only with the flue damper open, OR
• raise the mantel to an acceptable height, OR
• remove the mantel.
Figure 7 - Minimum Mantel Clearances When Using Hood
Figure 8 - Minimum Fireplace Clearances If Installed at Floor Level