Installation Instructions and Owner’s Manual
Unvented LP-Gas Vent Free Room Heaters
9.  To select the desired heat level, turn the 
temperature setting knob counterclockwise to 
between 1 & 5. 
THERMOSTAT CONTROL OPERATION
FOR IR20LPT / IR30LPT: The thermostatic control 
used simply turns on and off the burner. 
FOR BF20LPT / BF30LPT: The thermostatic control 
used modulates the flame size as the temperature gets 
closer to set point, then it turns off the burner upon 
reaching temperature.
The burner will cycle back on when room temperature 
drops below the set temperature. The control knob can 
be set to any heat level between 1 and 5. Selecting the 
HI setting will cause the burner to remain on.
TO TURN OFF GAS TO APPLIANCE
SHUTTING OFF HEATER
1.  Turn control knob clockwise to the OFF posi-
tion.
2.  Turn off all electrical power to the appliance if 
servicing is to be preformed.
3.  Turn off equipment shutoff valve.
SHUTTING OFF BURNER ONLY (PILOT STAYS LIT)
1.  Turn control knob clockwise to the PILOT/IGN 
position.
INSPECTING BURNER
Check pilot flame pattern and burner flame pattern 
often.
PILOT FLAME PATTERN
Figure 21 shows a correct pilot flame pattern. Figure 
22 shows an incorrect pilot flame pattern. The incorrect 
pilot flame pattern is not touching thermocouple. This 
will cause the thermocouple to cool. When the thermo-
couple cools, the heater will shut down. If pilot flame 
pattern is incorrect, as shown in Figure 22:
Turn heater off (see To Turn OFF Gas to Appli-
ance, above.
 
See Troubleshooting, pages 14-15.
CLEANING AND MAINTENANCE
WARNING: Turn off heater and let cool before 
servicing. 
CAUTION: You must keep control areas, burner 
and circulation air passageways of heater clean. 
Inspect these areas of heater before use. Have 
the heater inspected yearly by a qualified service 
person. Heater may need more frequent cleaning 
due to excess lent from carpeting, bedding material, 
pet hair, etc. 
Make sure grille guard is in place before running 
heater. If screen or grille guard is removed for 
servicing it must be replaced prior to operating the 
heater. 
push in or turn by hand, don’t try to repair it call 
a qualified service technician or gas supplier. 
Force or attempted repair may result in a fire or 
explosion.
D.  Do not use this appliance if any part has been 
underwater. Immediately call a qualified service 
technician to inspect the appliance and to re-
place any part of the control system which has 
been underwater.
LIGHTING INSTRUCTIONS
1.  STOP! Read the all safety information included 
with and on the side of heater.
2.  Make sure the equipment shutoff valve is fully 
open.
3.  Push in gas control knob and slightly turn clock-
wise to the OFF position (see figure 19).
4.  Wait five (5) minutes. Then smell for gas includ-
ing near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information above. If you 
do not smell gas, go to the next step.
5.  Push in and turn control knob counterclockwise 
to PILOT. Press in control knob for five (5) sec-
onds.
Note: The first time that the heater is operated after 
connecting the gas supply, the control knob should 
be depressed for about 30 seconds. This will allow 
air to bleed from the gas system. This may take 
longer in some installations
 Figure 19.
6.  With control knob pressed in, push down and 
release the ignition button. This will light pilot. If 
needed keep pressing igniter button until pilot 
lights.
7.  Keep control knob pressed in for (30) seconds 
after lighting pilot. After 30 seconds, release 
control knob. 
If pilot does not stay lit, refer to Troubleshoot-
ing, pages 14 & 15. Also, contact a qualified 
service person of gas supplier for repairs. 
If control knob does not pop up when released, 
contact a qualified service person or gas sup-
plier for repairs.
8.
   When the pilot is lit, turn control knob coun-
terclockwise to heating level. The main burner 
should light.
Ignitor Button
Control Knob