Enerco MHVFR30LPT Manual Do Utilizador

Página de 20
8
Installation Instructions and Owner’s Manual
Unvented LP-Gas Vent Free Room Heaters
1.  Drill holes at marked locations using 5/16” drill 
bit. For solid walls (concrete or masonry), drill 
at least 1” deep.
2.  Fold wall anchor as shown in figure 8 below.
Figure 8.
3.  Insert wall anchor (wings first) into hole. Tap 
anchor flush to wall.
4.  For thin walls (1/2” or less) insert red key into 
wall anchor. 
5.  Place mounting bracket onto wall. Line up 
holes on each end of bracket with wall anchors.
6.  Insert mounting screws through bracket and 
into wall anchors.
7.  Tighten screws until mounting bracket is firmly 
fastened to wall.
Placing Heater on Mounting Bracket
1.  Locate two horizontal slots on back pane of 
heater (see figure 9).
2.  Place heater onto mounting bracket. Slide hori-
zontal slots onto stand-out tabs on mounting 
bracket.
Figure 9. 
Installing Bottom Mounting Screws
1.  Locate two bottom mounting holes. These 
holes are near bottom on back panel of heater 
(see figure 10).
Figure 10
2.  Mark screws locations on wall.
3.  Remove heater from mounting bracket.
Horizontal Slots
Mounting Bracket 
mounted to wall
4.  If installing bottom mounting screw into hollow 
or solid wall, install wall anchors. Follow steps 1 
through 4 under Attaching to Wall using Anchor. 
If installing bottom mounting screw into wall 
stud, drill holes at marked locations using 9/64” 
drill bit.
5.  Re-place heater onto mounting bracket.
6.  Place spacers between bottom mounting holes 
and wall anchor or drilled hole.
7.  Hold spacer in place with one hand. With the 
other hand, insert mounting screw through 
bottom mounting hole and spacer. Place tip of 
screw in opening of wall anchor or drilled hole.
8.  Tighten both screws until heater is firmly se-
cured to wall. Do not over tighten.
Note: Do not re-place front panel at this time. Re-
place front panel after making gas connections and 
checking for leaks.
FLOOR MOUNTING AWAY FROM WALL:
Figure 11
Installing Support Feet (see figure 11)
1.  Lay heater onto table on its back with bottom 
edge overhanging table edge.
2.  Securely attach feet to bottom of heater using 
2 – self-tapping screws each.
Note: Feet should have long end going out the 
front of heater, and the edge coinciding with side of 
heater. If feet overhang side of the heater, switch 
leg location.
3.  Place heater on non-combustible surface (see 
Locating Heater above) before proceeding with 
gas connection. If this will be a permanent loca-
tion, heater may be locked into position using 
anchoring holes in mounting feet.
Note: Use of floor mounting feet will require you to 
use a 3/8 NPT street elbow to make gas connection.
CONNECTING TO GAS SUPPLY
WARNING: A qualified service person must con-
nect heater to gas supply. Follow all local codes. 
Screw  
hole
Screw  
hole