5.  Turn  control  knob  counterclockwise 
 to the PILOT position. Press in 
control  knob  for  five  (5)  seconds  (see 
Figure 31).
 
Note:  You  may  be  running  this  heater 
for the first time after hooking up to gas 
supply. If so, the control knob may need 
to be pressed in for 30 seconds or more. 
This will allow air to bleed from the gas 
system.
• If control knob does not pop out when 
released,  contact  a  qualified  service 
person or gas supplier for repairs.
6.  With control knob pressed in, press and 
release ignitor button. This will light pilot. 
The pilot is attached to the front burner. If 
needed, keep pressing ignitor button until 
pilot lights.
 
Note: If pilot does not stay lit, contact a 
qualified service person or gas supplier 
for repairs. Until repairs are made, light 
pilot with match. To light pilot with match, 
see Manual Lighting Procedure.
7.  Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds, 
release control knob.
 
Note: If pilot goes out, repeat steps 3 
through 7. This heater has a safety inter-
lock system. Wait one (1) minute for sys-
tem to reset before lighting pilot again.
8.  Turn  control  knob  counterclockwise 
 to desired heating level. The burn-
ers should light. Set control knob to any 
heat level between HI and LO.
9.  Turn control knob clockwise 
 to the 
PILOT position to shut off burner leaving 
pilot lit.
TO TURN OFF GAS 
TO APPLIANCE
1.  Turn control knob clockwise 
 to the 
OFF position.
2.  Close equipment shutoff valve (see Figure 
16, page 15).
THERMOSTAT 
CONTROL OPERATION
The thermostat control knob can be set to any 
comfort level between HI and LO. The ther-
mostat will gradually modulate the heat output 
and flame height from higher to lower settings 
or pilot, in order to maintain the comfort level 
you select. The ideal comfort setting will vary 
by household depending upon the amount of 
space to be heated, the output of the central 
heating system, etc.
Note: Selecting the HI setting with the control 
knob will cause the burners to remain fully on, 
without modulating down in most cases.
MANUAL LIGHTING 
PROCEDURE
1.  Follow steps 1 through 5 under Lighting 
Instructions, page 21.
2.  Press  control  knob  and  light  pilot  with 
match.
3.  Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds, 
release control knob. Now follow step 8, 
under Lighting Instructions, column 1.
Figure 24 - Control Knob and Ignitor 
Button Location
Figure 25 - Pilot
LO
HI
OFF
Pilot
Control Knob
Ignitor Button
Thermocouple
Pilot Burner
Ignitor 
Electrode
OPERATION
Continued
THERMOSTAT-CONTROLLED MODELS