Essick Air N50W Manual Do Utilizador

Página de 12
3
110496-1
•  Install window panel 
retainers.  Place two 
panel retainer strips onto 
bottom of neck flange 
and position to the width 
of the window.  Cut the 
strips to fi t if necessary.  
These strips hold  the 
window fill-in panels 
(Fig. 3).
•  Position cooler in win-
dow.  Position neck of 
cooler so that bottom of neck fl ange rests on window sill and fl ange 
(E-Fig. 2) is snug against edge of sill (H-Fig. 2).  With cooler in 
position, hook the “S” hooks into the holes of the top pan near the 
back of the cooler (B-Fig. 2).
•  Break  fi ll-in panels to fi t.  With cooler installed, as described 
above, measure for each window fi ll-in panel and score with sharp 
knife and straight edge guide to desired width.  To break window 
fi ll-in panels, the panel should be laid over the edge of a straight fl at 
surface at the point to be broken off.  Apply pressure on the edge 
of the panel that extends over the edge of the surface and break off 
unwanted piece.
•  Install fi ll-in panels.  Place one window fi ll-in panel on each side 
of grill and into panel retainer strip at bottom of grill.  Place the 
other panel retainer strips onto top of neck fl ange and fi ll-in panels.  
Be sure the panels are snug up against cooler neck.
•  Place window behind retainer strip.  Raise back of cooler so that 
the window (D-Fig. 2) may be brought down behind top of panel 
retainer strip (C-Fig. 2).
•  Level Cooler.  Adjust the chains to level the cooler.
•  Adjust house legs.  Pull out house legs so that the rubber bumpers 
rest against house siding (F-Fig. 2).  Tighten screw in retaining 
collar. (G-Fig. 2).
Connecting Water
•  Install overfl ow  assembly.  Remove 
nut and place nipple through the hole in 
the pan, with the rubber washer between 
the pan and the head of the drain nipple 
(Fig. 4).  Screw on  nut and draw up tight 
against bottom of pan.  Insert overfl ow 
pipe in nipple to retain water.  Overfl ow 
pipe may be removed to drain pan when 
necessary.  A garden hose may be 
screwed on the drain nipple to 
drain water away from your unit.
•  Connect water supply line.  In-
stall a sillcock and water valve on 
faucet as shown by fi gure 5.  Place 
the nut and ferrule on the tubing 
and tighten the nut until water 
tight.
Maintenance
WARNING:
  Before doing any maintenance be sure power is 
off and unit is unplugged.  This is for your safety.
Spring Start-Up
•  Oil bearings.  The blower bearings and cooler motor in this unit 
should be oiled with a few drops of non-detergent 20/30 weight oil 
once each year.  The motor does not need oil if it has no oil lines 
for oiling.  Motors that have no oil lines are lifetime oiled at the 
factory and require no further oiling for the life of the unit.
CAUTION:
  Do not over oil.  
Over oiling can cause motor burn 
out, due to excessive oil getting into 
motor winding.
•  Check belt tension.  A 3 lb. force 
should defl ect the belt 3/4 inches (see 
Fig. 7).  Readjust belt if needed.
•  Clean pump.  Cleaning the pump is necessary once a year at start-
up.  For your safety, turn unit off and unplug from power receptacle.  
Remove the pump from the mount slot.  Remove the base of the 
pump as shown in Fig. 8.  Clean the pump and turn the impeller 
to ensure free operation.  Remove the pump spout and check for 
any blockage.  After cleaning, 
reinstall the base onto the pump.  
Press  fi rmly to make sure it is 
secure.  Reattach the pump to 
the mount in the cooler using 
the plastic retainer to ensure that 
the pump will not overturn.  Do 
not forget to replace the spout 
and water delivery tube onto the 
pump outlet.
•  Replace Pads.  Aspen pads should be replaced once or twice a 
season, depending upon the length of the season.  At the beginning 
and at mid season a clean pad is more absorbent and effi cient and 
will deliver substantially more cool air.
Winter Shut Down
•  Drain water.  Always drain all of the water out of the cooler and 
water supply line when not in use for prolonged periods, and par-
ticularly at the end of the season.  Keep the water line disconnected 
from both the unit and water supply so that it does not freeze.
•  Cover unit.  To protect the life of the fi nish, a cover for the unit is 
suggested in extended periods of non use.
•  Install  fl oat  valve.  Install 
valve in the provided hole in 
corner post (Fig. 6) and attach 
water supply line.
•  Fill pan.  Allow water to fi ll 
to within 1” of the top of the 
overfl ow pipe and adjust fl oat 
to maintain this water level.  
This can be accomplished by 
bending the float rod (Fig. 
6).
Impeller
Remove
Base
Fig. 8
Fig. 3
Window Fill-In 
Panels
Top Panel 
Retainer
Bottom Panel 
Retainer
Rubber Washer
Overfl ow Pipe
Nipple
Bottom Pan
Nut
Fig. 4
Faucet
W
ater Supply 
V
alve
Sillcock
Ferrule
Nut
Fig. 5
Float Rod
Water Supply 
Line
W
asher
Nut
Ferrule
Nut
Fig. 6
Corner Post
Fig. 7
3 Lb.
3/4 Inches