Essick Air AS1C5112 Manual Do Utilizador

Página de 16
Models
 AD1C51 
AD2C51
 AS1C51 
AS2C51
 AD1C5112 
AD2C5112
 AS1C5112 
AS2C5112
 AD1C71 
AD2C71
 AS1C71 
AS2C71
 AD1C7112 
AD2C7112
 AS1C7112 
AS2C7112
 AU1C7112 
AU2C7112
Circle the model of your cooler and 
record the serial number below.
Read Carefully All Of This Manual 
Before Installing The Unit
Encierrre con un circulo el modelo de su 
enfriador y escribe el número de série abajo.
Lea Con Cuidado Todo Este Manual Antes De 
Instalar La Unidad
Serial #
Número De Série
Safety Rules
1.  Read instructions carefully.
2.  Electrical hook up should be done by a qualifi ed electrician, so 
that all electrical wiring will conform to your local standards.
3. Always DISCONNECT POWER and UNPLUG motor and 
pump inside the cooler before installing or performing any 
maintenance.
4.  Motor and pump have a grounded, molded plug and an automatic 
thermal overload switch which will shut motor off when it 
overheats.  The motor will restart automatically when it cools 
down.
WARNING:
  To reduce the risk of fi re or electric shock, do not 
use this fan with any “solid-state fan speed control device.”
Read And Save These Instructions
Vea el Español en el interior.
110498-3
9-09
www.championcooler.com
Table Of Contents
Safety Instructions .......................................................................1
Installation Instructions ............................................................ 2-3
Electrical Wiring Diagram ...........................................................3
Operation .................................................................................. 3-4
Maintenance Section ....................................................................4
Troubleshooting ...........................................................................5
Warranty .......................................................................................5
Parts List (Down Discharge Units) .......................................... 6-7
Parts List (Side Discharge Units) ............................................. 8-9
Parts List (Up Discharge Units) ........................................... 10-11
Specifi cation Tables (Tablas de Especifi caciones) .....................12
Instrucciones en Español ..................................................... 12-16
Evaporative Cooling
Evaporative cooling is nature’s way of cooling.  When air is moved 
over a wet surface, water is evaporated and heat is absorbed.  When 
stepping out of swimming pool with the wind blowing, evaporative 
cooling makes you feel cool, even though the air may be warm.
This unit works on the same principle.  Air is drawn across wet 
fi lter pads where the air is cooled by evaporation and then circulated 
throughout the building.  It is this combination of cooled air and the 
movement of air over the skin which makes it feel cool.
Unlike refrigeration systems which recirculate the air, an evaporative 
cooler continually brings in fresh air while exhausting old air.  You 
are completely replacing the air every 2 to 4 minutes by opening 
windows or doors or a combination of both.  The air is always fresh, 
not stale, laden with smoke and odors as happens with refrigerated 
air conditioning.