England's Stove Works 26-GUHLP Manual Do Utilizador

Página de 13
TROUBLE SHOOTING GUIDE 
 
ITEMS IN THIS GUIDE MARKED WITH AN ASTERISK (*) SHOULD ONLY BE  
PERFORMED BY A LICENSED GAS FITTER OR EQUIVALENT. 
 
 
 
WARNING
 
 
 
 
CAUTION 
 
 
 
Turn off and let the unit cool before servicing. 
Never use a wire, needle, or similar 
 
Only a qualified service person should 
 
object to clean the ODS pilot. 
 
service or repair this unit.
 
 
 
This can damage the pilot. 
 
    PROBLEM                                       POSSIBLE CAUSE 
 
      SOLUTION 
 
 
When ignitor is pressed  
 
Ignitor electrode positioned wrong. 
→   
*Replace ignitor electrode. 
there is no ODS pilot. 
   Ignitor 
electrode 
broken. 
→ 
  *Replace 
ignitor 
electrode. 
 
 
 
 
 
Ignitor electrode not connected 
 
 
 
  
to ignitor cable. 
→ 
   *Replace 
ignitor 
cable. 
 
 
 
 
 
 
Ignitor cable pinched or wet. 
→  
 
*Free ignitor cable if pinched                         
by any metal or tubing. Keep 
ignitor cable dry. 
Replace cable if spark still 
isn’t there after freeing the 
pinched wire. 
 
 
 
Flame seems to blow out 
 
Air in the gas line.
→  
 
 
Purge air from line (Check to  
or 
will 
not 
light. 
       ensure 
gas 
is 
going 
to 
pilot.) 
 
Appliance produces odors. 
 
Stove burning vapors from paint, 
 
Ventilate room. Stop using 
    hair 
spray, 
glue, 
etc.
→ 
  products 
while 
operating 
unit. 
 
 
 
 
 
Gas leak. See warning label on cover.
→  
*Locate and correct all leaks. 
 
Gas odor even when control   
Gas leak. See warning label on cover.
→  
*Locate and correct all leaks. 
knob is in “OFF” position. 
    Control 
valve 
defective.
→ 
  *Replace 
control 
valve. 
 
Smoke or odor during initial burn. 
Vapors from paint or production process.
→ 
Unit curing out. Will stop. 
 
Strong gas smell. 
 
 
LP fuel may have additives or be poor quality.
→  *Shut off gas. Check supplier. 
 
    Excess 
gas 
pressure.
→ 
  *Call 
utility 
company/installer. 
 
Gas smell – sooting. 
 
Logs may be out of place.
→   
 
Compare placement of logs to 
         the 
diagram 
in 
the 
manual. 
 
    Orifice 
size 
may 
be 
incorrect.
→ 
 
Replace if incorrect. 
 
When ignitor button is pressed, 
Gas supply turned off or manual shutoff   
 
there is spark at ODS and no ignition. valve 
is 
closed.
→   
 
 
Turn on gas or open supply. 
 
    Control 
knob 
not 
in 
“PILOT” 
position.
→   
Correct knob position. 
 
 
 
 
 
Air in gas line when installed.
→ 
 
Purge air from system by  
         holding 
down 
control 
knob. 
         Repeat 
ignition. 
 
    “ODS” 
pilot 
is 
clogged.
→ 
  *Replace 
“ODS” 
assembly. 
 Gas regulator setting is incorrect.
→ 
 
*Replace gas regulator.