Hunter Fan 27188 Manual Do Utilizador

Página de 11
10
41797-01  •  07/06/10  •  Hunter Fan Company
7  •  Troubleshooting
Symptom
Possible Causes
Solution
1.No functions operate.
Main Power not restored.
Replace fuse. Turn ON circuit breaker. Turn ON wall switch.
Fan pull chain not set to High. Set fan pull chain to High speed.
Light pull chain not set to ON. Set light kit to ON. 
Receiver wiring incorrect.
Verify wiring connections.
Transmitter and receiver DIP 
switches do not match.
Set transmitter and receiver to same DIP switch setting.
Battery too weak.
Replace with new, 12 Volt alkaline battery.  Refer to 
“Transmitter Installation”, Section 6. 
2.Operates only at close range. Signal blocked from reaching 
receiver.
Extend antenna into ceiling box, or move it for better 
reception. 
Battery too weak.
Replace with new, 12 Volt alkaline battery.  Refer to 
“Transmitter Installation”, Section 6. 
Interference
Change the DIP switch settings on the remote receiver and 
transmitter,
3.Inconsistent operation. 
Signal partially blocked from 
reaching receiver.
Extend antenna into ceiling box, or move it for better 
reception. 
RF interference.
Turn OFF wall switch for 5 seconds, then turn back ON.
Continuing RF interference.
Change jumper settings to a different code in both transmitter 
and receiver.