Hunter Fan Type T Models Manual Do Utilizador
7
42747-01 • 09/21/07 • Hunter Fan Company
All wiring must be in accordance with national and local electrical
codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a
qualified electrician.
Wall switches are not included. Select an acceptable general-use switch
in accordance with national and local electrical codes.
4-1. Make sure the power to the outlet box and associated wall switch
codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a
qualified electrician.
Wall switches are not included. Select an acceptable general-use switch
in accordance with national and local electrical codes.
4-1. Make sure the power to the outlet box and associated wall switch
location is still OFF.
4-2. To connect the wires, hold the bare metal leads together and
place a wire connector over them, then twist the wire connector
clockwise until tight.
clockwise until tight.
4-3. Connect the bare or green ground wired (grounded) from the
ceiling to the green ground wire (grounded) from the ceiling plate
and the green ground wire from the fan.
and the green ground wire from the fan.
4-4. Connect the white wire (ungrounded) from the ceiling to the
white wired (ungrounded) from the fan.
4-5. Connect the remaining wires as follows:
Single Switch Wiring:
• The black wire from the ceiling to the black and the black/
white wire from the fan.
Dual Switch Wiring:
• The black wire from the ceiling to the black wire from the fan.
• The black/white wire from the fan to the wire for the wall
• The black wire from the ceiling to the black wire from the fan.
• The black/white wire from the fan to the wire for the wall
switch.
CAUTION: Be sure no bare wire or wire strands are visible after
making connections.
4-6
Turn the splices upward and push them carefully back through the
ceiling plate into the outlet box.
4-7 Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the
outlet box.
outlet box.
4 • Wiring the Fan
Wire
connector
Step 4-3
Step 4-4