Rinnai REU-V2520FFUD Manual Do Utilizador

Página de 48
HOT
HOT
COLD
COLD
ON!
ON!
NOTE: TEMPERATURE CANNOT BE 
ADJUSTED EXCEPT BETWEEN 98°F AND 110
°F WHEN ANY HOT WATER TAP IS OPEN.
NOTE: CHECK LOCAL CODES FOR 
THE MAXIMUM WATER TEMPERATURE 
SETTING ALLOWED WHEN USED IN 
NURSING HOMES, SCHOOL, DAY CARE 
CENTERS, AND ALL OTHER PUBLIC 
APPLICATIONS.
NOTE: If a newly installed unit has not 
been powered for at least six hours then 
the temperature will return to the default 
setting if power is interrupted.
CHECK WATER 
TEMPERATURE BEFORE 
ENTERING SHOWER OR 
BATH.
There is a hot water 
scald potential if the 
thermostat is set to high.
Rinnai America
FF  Models
B A S I C   O P E R A T I O N
To operate the  Rinnai  Water  Heater 
simply  turn  any  hot  water  tap  on. 
This  will  automatically  light  the  burner 
providing  hot  water  at  the  preset 
temperature.  If  the  optional  remote 
controller(s)  have  been  installed,  the 
red  “IN  USE”  indicator  will  glow  on 
all  remote  controller(s). 
Adjusting Temperature
  1
To  take  control  of  the  Rinnai  Water  Heater 
all  hot  water  taps  must  be  closed.  Press 
the  "Priority  button"  on  the  Controller  you 
want  to  set  the  temperature  with,  and 
the  green  "Priority"  indicator  light  will 
The  outlet  water  temperature  of  the  Rinnai 
Water  Heater  can  only  be  adjusted  by 
the  user  using  the  remote  controller(s). 
To  adjust  the  setpoint  temperature  of 
the  Rinnai  Water  Heater,  all  hot  water 
taps  must  be  closed,  and  all  circulating 
pumps  turned  off  (where  applicable). The 
temperature  displayed  on  this  remote 
controller  will  also    be  displayed  on  all 
other  remote  controller(s). 
    
Simply  press  the 
  or 
  button 
until  the  required  temperature  is 
displayed  on  the  Digital  Monitor. 
glow. This  indicates  that  the  Rinnai  Water 
Heater  is  ready  to  supply  hot  water  at 
the  set  temperature  as  soon  as  a  tap  is 
opened. 
Note:  Rinnai  Water  Heater  will  not  provide 
hot  water  instantly  at  the  hot  water 
fixtures. Any  cold  water  existing  in  the  hot 
water  lines  must  be  purged  first.