Empire Products FAW-55IP Manual Do Utilizador

Página de 20
Green LED Status Codes
Green LED 
Flash Code 
(X + Y)
a
Indicates
Next System Action
Recommended Service Action
OFF
No “Call for Heat”
Not applicable
None
Flash Fast
Startup-Flame sense calibration
Not applicable
None
Heart Beat
Normal operation
Not applicable
None
3
Recycle
  - Flame failed during run
Initiate new trial for ignition. Flash code 
will  remain  through  the  ignition  trial 
until flame is proved.
If system fails to light on next trial for 
ignition, check gas supply, pilot burner, 
flame  sense  wiring,  contamination  of 
flame rod, burner ground connection.
4
Flame sensed out of sequence
If situation self corrects within 10 sec-
onds, control returns to normal sequence. 
If flame out of sequence remains longer 
than 10 seconds, control goes to Flash 
code 6 + 4 (see below).
Check for pilot flame. Replace gas valve 
if pilot flame present. If no pilot flame, 
cycle  “Call  for  Heat.”  If  error  repeats, 
replace control.
7
Flame sense leakage to ground
Control  remains  in  wait  mode.  When 
the fault corrects, control resumes nor-
mal operation after a one minute delay.
Check flame sense lead wire for damage 
or shorting. Check that flame rod is in 
proper position.
Check  flame  rod  ceramic  for  cracks, 
damage or tracking.
8
Low  secondary  voltage  supply  -  
below 15.5 Vac)
Control  remains  in  wait  mode.  When 
the fault corrects, control resumes nor-
mal operation after a one minute delay.
Check transformer and AC line for proper 
input voltage to the control. Check with 
full system load on the transformer.
6 + 2
Failed trial for ignition resulting 
in lockout
Remain in lockout until “Call for Heat” 
is cycled.
Check  gas  supply,  pilot  burner,  spark 
and flame sense wiring, flame rod con-
taminated  or  out  of  position,  burner 
ground connection.
6 + 3
More than 5 flame failures during 
run on the same “Call for Heat” 
resulting in lockout
Remain in lockout until “Call for Heat” 
is cycled.
Check  gas  supply,  pilot  burner,  flame 
sense  wiring,  contamination  of  flame 
rod, burner ground connection.
6 + 4
Flame  sensed  out  of  sequence  -  
longer than 10 seconds
Control  waits  until  flame  is  no  longer 
sensed  and  then  goes  to  soft  lockout. 
Flash code continues. Control auto re-
sets from soft lockout after one hour.
Check for pilot flame. Replace gas valve 
if pilot flame present. If no pilot flame, 
cycle  “Call  for  Heat.”  If  error  repeats, 
replace control.
ON
Soft lockout due to error detected 
during self check sequences
Control auto resets from soft lockout af-
ter one hour.
Reset by cycling “Call for Heat.” If er-
ror repeats, replace the control.
a
Flash Code Descriptions:
  -  Flash Fast: Rapid blinking
  -   Heartbeat: Constant 1/2 second bright 1/2 second dim cycles
  -  A single flash code number signifies that the LED flashes X times at 2Hz, remains off for two seconds, 
and then repeats the sequence.
  -  X + Y flash codes signify that the LED flashes X times at 2Hz, remains off for two seconds, flashes Y 
times at 2Hz, remains off for three seconds, and then repeats the sequence.
12429-10-0408
Page 15
S8600H TROUBLESHOOTING GUIDE